Evergreen Ridge Apartments
3030 W SPENCER ST, Appleton, WI 54914 · Outagamie County
Establishment
- Type
- Pool / recreational water (Swimming)
- Inspected by
- Outagamie County Public Health
- License / ID
- PHAL-CF2SS3
- Status
- Permitted
- Phone
- (920) 413-1471
- Official record
- Outagamie County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 5 | 2 |
| 2025 | 1 | 0 | 0 |
| 2024 | 1 | 3 | 1 |
Inspections
-
Jun 3, 2026 Routine · 2 critical, 3 non-critical
-
Not serious
Non-critical
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer or screen not available
Correction: Provide a spare strainer or screen
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. Guage states 40 gal per minute].
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate [Describe].
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
FLOW-THROUGH FEEDERS-USE
The chlorine system was not operational at the time of inspection. The facility has been hand feeding in chlorine.
Correction: The chlorine system needs to be operational as well as the comptroller monitering chlorine and ph in the pool water.
Code ATCP 76.14 (4)(b) - FLOW-THROUGH CHEMICAL FEEDER
-
Serious
Critical
TELEPHONE ACCESSIBLE
A telephone or other approved communication technology capable of connecting to emergency services is not working or not present.
Correction: Provide a working telephone or other technology capable of connecting with emergency services.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Serious
Critical
Corrected on site
GATES AND DOORS-LATCHING
The gate or door does not latch. The entry exit doors did not latch .
Correction: Provide a latching door. The maintence person put a new spring on the door do that is does now latch.
Code ATCP 76.34(4)(a)(1m)(b)- LATCHING
-
Not serious
Non-critical
-
Jun 2, 2025 Routine · No items found
No violations cited.
-
May 29, 2024 Routine · 1 critical, 2 non-critical
-
Not serious
Non-critical
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool. Kit will arrive by 6/1/24 Pictures will be sent to verify.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
EMERGENCY BLANKETS
Two emergency blankets in good condition are not available in the pool area.
Correction: Provide two emergency blankets in good condition in the pool area. Blankets will arrive by 6/1/24. Pictures will verify.
Code ATCP 76.27(3) - EMERGENCY BLANKETS
-
Serious
Critical
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.
Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located. First aid will arrive by 5/1/24. Pictures will be sent to verify.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Not serious
Non-critical
Source: Outagamie County Public Health. History last read Oct 19, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.