Spark By Hilton Appleton
321 METRO DR, Appleton, WI 54914 · Outagamie County
Establishment
- Type
- Pool / recreational water (Whirlpool)
- Inspected by
- Outagamie County Public Health
- License / ID
- KGRN-9XEJ6U
- Status
- Permitted
- Phone
- (920) 997-3121
- Official record
- Outagamie County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 3 | 5 | 4 |
| 2025 | 2 | 3 | 2 |
Inspections
-
Apr 9, 2026 Re-inspection 2 · 1 critical, 1 repeat
-
Serious
Critical
Repeat
Corrected on site
MINIMUM DISINFECTANT RESIDUAL
Tested at **17 ppm then retested at 9ppm for bromine.
Correction: Discussed with the operator. Operator retested the bromine manually and it came to be at 9 ppm.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Repeat
Corrected on site
-
Apr 6, 2026 Re-inspection · 1 critical, 1 repeat
-
Serious
Critical
Repeat
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level was tested at ***0.79 for bromine.
Correction: Discussed with the operator. Operator stated they are keeping it closed and will be contacting a pool company to come out to see if there is a larger issue. Whirlpool shall close until the disinfectant level between 4.0ppm - 10ppm. A 2nd charged re-inspection shall take place within 3 days to verify the whirlpool is within concentration limits. Failure to comply shall result in a charged re-inspec
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Repeat
-
Mar 31, 2026 Routine · 2 critical, 1 non-critical
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 618 mV and water has not been tested manually.
Correction: Discussed with the operator. Operator shall ensure the water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV within 10 days. Compliance will be determined during the next routine inspection. Failure to comply may result in additional follow up actions.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level was tested at ***0.84 for bromine.
Correction: Discussed with the operator. Whirlpool shall close until the disinfectant level between 4.0ppm - 10ppm. A re-inspection shall take place within 3 days to verify the whirlpool is within concentration limits. Failure to comply shall result in a charged re-inspection of $103.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
CLOSING CRITERIA-FAILURE TO COMPLY WITH 76.14 OR PH LIMITS
The Responsible Supervisor or operator has not closed the pool after failure to comply with the bromine minimum standards of 4.0ppm for whirlpools.
Correction: Discussed with operator. Close the whirlpool in the event of failure to comply with the bromine minimum standards of 4.0ppm for whirlpools. Compliance will be determined during the re-inspection within 72 hours. Failure to comply will result in a charged re-inspection of $103.
Code ATCP 76.30 (1)(c) - FAILURE TO COMPLY WITH ATCP 76.14
-
Not serious
Non-critical
-
Mar 5, 2025 Re-inspection · No items found
No violations cited.
-
Feb 26, 2025 Routine · 2 critical, 1 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 32.
Correction: Person-In-Charge shall ensure maintain the total alkalinity of the water between 60 and 180 ppm within 7 days. Compliance will be determined during the re-inspection in 7 days. Failure to comply will result in a charged re-inspection of $103.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Serious
Critical
PH
The pH is 6.6.
Correction: Operator tested the pH and it was out of range. Person-in-charge (PIC) shall ensure the pH at 7.2 to 7.8. Compliance will be determined during the re-inspection in 7 days. Failure to comply will result in a charged re-inspection of $103.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Repeat
MAXIMUM BROMINE
Maximum total bromine was tested at 11 ppm.
Correction: Person-In-Charge re-tested and got 13 ppm. PIC shall close the pool until the total bromine residual is 10 ppm or under. Compliance will be determined during the re-inspection in 7 days. Failure to comply will result in a charged re-inspection of $103.
Code ATCP 76.14(5)(g) -MAXIMUM BROMINE
-
Not serious
Non-critical
Repeat
Source: Outagamie County Public Health. History last read Oct 19, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.