Country Inn & Suites Swimming Pool
130 PATRIOT DR, Little Chute, WI 54140 · Outagamie County
Establishment
- Type
- Pool / recreational water (Swimming)
- Inspected by
- Outagamie County Public Health
- License / ID
- JVUE-DC8N4V
- Status
- Permitted
- Official record
- Outagamie County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 5 | 1 |
| 2025 | 2 | 4 | 1 |
| 2024 | 1 | 5 | 2 |
Inspections
-
Jul 28, 2026 Routine · 1 critical, 4 non-critical, 1 repeat
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is at 47 PPM.
Correction: Notified operator. Operator shall maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water within 30 days. This will be reviewed during the next routine inspection. Failure to comply may result in further enforcement actions.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
REAGENTS REPLACED
Multiple bulk containers of test kit reagents are not replaced as recommended by the manufacturer and or passed its expiration date.
Correction: Operator shall discard expired reagents. Replace test kit reagents as recommended by the manufacturer within 30 days. This will be reviewed during the next routine inspection. Failure to comply may result in further enforcement actions.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
EMERGENCY BLANKETS
Two emergency blankets in good condition are not available in the pool area.
Correction: Operator shall provide two emergency blankets in good condition in the pool area within 30 days. This will be reviewed during the next routine inspection. Failure to comply may result in further enforcement actions.
Code ATCP 76.27(3) - EMERGENCY BLANKETS
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Notified operator. Operator shall provide signage or provide other communication warning against prolonged breath holding within 30 days. This will be reviewed during the next routine inspection. Failure to comply may result in further enforcement actions.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Serious
Critical
Repeat
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve or drain cover specifications.
Correction: Notified operator. Operator shall obtain a pump curve and information that describes make, model and gpm rating for the drain covers within 30 days. Once obtained, operator shall sent proof of curve and information to Outagamie County Public Health for verification. Failure to comply will result in a re-inspection.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
-
Jul 2, 2025 Routine · 1 critical, 1 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not operational and cannot be used to determine turnover rate.
Correction: Notified person-in-charge (PIC). PIC shall service or replace the affected flow meter within 30 days. This will be reviewed during the next routine inspection. Failure to comply may result in further enforcement actions.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve or drain cover specifications.
Correction: Operator shall obtain a pump curve and information that describes make, model and gpm rating for the drain covers and retain for review within 30 days. This will be reviewed during the next routine inspection. Failure to comply will result in a re-inspection.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
-
Feb 19, 2025 Pre-inspection Follow Up · 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
SKIMMER POOL RECIRCULATION FLOW
Proportion of water recirculating from skimmer and main drain is opened all the way for both valves.
Correction: Notified person-in-charge (PIC). PIC shall adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer or roughly 80/20% ratio. This will be reviewed during the next routine inspection. Failure to comply may result in further enforcement actions.
Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation turnover rate has not been met. Turnover over rate observed at 8.4 hours.
Correction: Notified person-in-charge (PIC). PIC shall immediately adjust or repair equipment to operate at a proper turnover rate to meet 6 hours or below. This will be reviewed during the next routine inspection. Failure to comply may result in further enforcement actions.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
-
Dec 26, 2024 Pre-inspection · 2 critical, 3 non-critical
-
Not serious
Non-critical
SKIMMER POOL RECIRCULATION FLOW
Proportion of water recirculating from skimmer and main drain is opened all the way for both valves.
Correction: Notified person-in-charge (PIC). PIC shall adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer or roughly 80/20% ratio. This will be reviewed during the next routine inspection. Failure to comply may result in further enforcement actions.
Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation turnover rate has not been met. Turnover over rate observed at 8.4 hours.
Correction: Notified person-in-charge (PIC). PIC shall immediately adjust or repair equipment to operate at a proper turnover rate to meet 6 hours or below. This will be reviewed during the next routine inspection. Failure to comply may result in further enforcement actions.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY INSTALLLED
The containment for the shepherds crook is in poor repair and not working to contain the shepherds crook.
Correction: Notified person-in-charge (PIC). PIC shall ensure that the pool equipment is properly installed within 30 days. This will be reviewed during the next routine inspection. Failure to comply may result in further enforcement actions.
Code ATCP 76.33(1)(e)2. - INSTALLATION OF POOL EQPT.
-
Serious
Critical
DRINKING FOUNTAIN PROVIDED
The water fountain provided is not in working order.
Correction: Notified person-in-charge (PIC). PIC shall provide a drinking fountain within 300 feet walking distance within 7 days. Failure to comply may result in license being suspended and or revoked.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Serious
Critical
WATER ATTRACTIONS-WATERSLIDES 6 FEET OR HIGHER, INSPECTION
A waterslide 6 feet or higher has not been inspected by an engineer or the signed report from the engineer is missing.
Correction: Notified person-in-charge (PIC). PIC shall have an engineer evaluate the waterslide for the structural stability and integrity of the slide and platform and maintain the signed report from the engineer within 30 days. Once obtained, operator shall email a copy of the report for review to Outagamie County Public Health. Failure to comply may result in license suspension and or revocation.
Code ATCP 76.37(2)(c) - WATERSLIDE INSPECTED BY ENGINEER
-
Not serious
Non-critical
Source: Outagamie County Public Health. History last read Oct 19, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.