RecordWell Data

Jacobus Park Pool

9480 WATERTOWN PLANK RD, Wauwatosa, WI 53226 · Milwaukee County

7cited violations
3serious tier
4inspections

Establishment

Type
Pool / recreational water (Wading)
Inspected by
City of Wauwatosa Health Department
License / ID
CHUS-AS2QD4
Status
Permitted
Phone
(414) 257-4782
Official record
City of Wauwatosa Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026173
2025100
2024100
2023100

Inspections

  1. Aug 10, 2026 Routine · 3 critical, 4 non-critical
    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Most of the reagents in the test kit have expired. Liam stated that new reagents are added to old bottles of different origin after they are rinsed.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      TELEPHONE-OTHER TECHNOLOGIES, POWER SUPPLY

      Flip phone does not have connection to permanent power supply. Please see attached fact sheet for acceptablel alternatives.

      Correction: Provide a connection to permanent power supply.

      Code ATCP 76.26(2)(b)1. - TELEPHONE, OTHER TECHNOLOGIES, POWER

    • Not serious Non-critical

      POSTING SIGNAGE-MAX PATRON LOAD

      Maximum patron load is not posted.

      Correction: Post signage indicating Maximum patron load.

      Code ATCP 76.29(1)(e) - MAX PATRON LOAD

    • Not serious Non-critical

      POOL BASIN MAINTAINED FREE OF DEFECTS

      Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. The pool basin has sealed joints in the concrete. These joints have sunk over time and are now accumulating dirt and debris. The joints may also be concidered a trip or injury hazard.

      Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.

      Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR

    • Serious Critical Corrected on site

      PH

      The pH is 8.2. pH down was added at the time of my inspection and the level was deceased to a pH within acceptable limits.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications. The drain cover log is present, but there is no pump curve or pump/drain specification information on site.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  2. Aug 22, 2025 Routine · No items found

    No violations cited.

  3. Oct 3, 2024 Routine · No items found

    No violations cited.

  4. Aug 7, 2023 Routine · No items found

    No violations cited.