Jacobus Park Pool
9480 WATERTOWN PLANK RD, Wauwatosa, WI 53226 · Milwaukee County
Establishment
- Type
- Pool / recreational water (Wading)
- Inspected by
- City of Wauwatosa Health Department
- License / ID
- CHUS-AS2QD4
- Status
- Permitted
- Phone
- (414) 257-4782
- Official record
- City of Wauwatosa Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 7 | 3 |
| 2025 | 1 | 0 | 0 |
| 2024 | 1 | 0 | 0 |
| 2023 | 1 | 0 | 0 |
Inspections
-
Aug 10, 2026 Routine · 3 critical, 4 non-critical
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. Most of the reagents in the test kit have expired. Liam stated that new reagents are added to old bottles of different origin after they are rinsed.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
TELEPHONE-OTHER TECHNOLOGIES, POWER SUPPLY
Flip phone does not have connection to permanent power supply. Please see attached fact sheet for acceptablel alternatives.
Correction: Provide a connection to permanent power supply.
Code ATCP 76.26(2)(b)1. - TELEPHONE, OTHER TECHNOLOGIES, POWER
-
Not serious
Non-critical
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load is not posted.
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Not serious
Non-critical
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. The pool basin has sealed joints in the concrete. These joints have sunk over time and are now accumulating dirt and debris. The joints may also be concidered a trip or injury hazard.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Serious
Critical
Corrected on site
PH
The pH is 8.2. pH down was added at the time of my inspection and the level was deceased to a pH within acceptable limits.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve or drain cover specifications. The drain cover log is present, but there is no pump curve or pump/drain specification information on site.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
-
Aug 22, 2025 Routine · No items found
No violations cited.
-
Oct 3, 2024 Routine · No items found
No violations cited.
-
Aug 7, 2023 Routine · No items found
No violations cited.
Source: City of Wauwatosa Health Department. History last read Oct 22, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.