Normandy Village Pool

2562 N 124 ST, Wauwatosa, WI 53226 · Milwaukee County

20cited violations
9serious tier
6inspections

Establishment

Type
Pool / recreational water (Swimming)
Inspected by
City of Wauwatosa Health Department
License / ID
CAMN-CGJPEK
Status
Permitted
Official record
City of Wauwatosa Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026100
2025262
2024181
2023266

Inspections

  1. Jun 29, 2026 Routine · No items found

    No violations cited.

  2. Jul 9, 2025 Re-inspection · No items found

    No violations cited.

  3. Jul 8, 2025 Routine · 2 critical, 4 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition. It is not reading the flow.

      Correction: Adjust or repair the [ ].

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 625 mV.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      POSTING SIGNAGE-SUPERVISION OF CHILDREN

      At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present.

      Correction: Post signage stating that children under 12 must be supervised.

      Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN

    • Not serious Non-critical

      POOL BASIN ROUTINELY BRUSHED, VACUUMED

      Pool basin is not routinely brushed or vacuumed to keep the basin and surrounding appurtenances free of sediment and debris.

      Correction: Routinely brush or vacuum the pool basin to keep the basin and surrounding appurtenances free of sediment, lint, hair, debris, algae, and slime growth and discoloration.

      Code ATCP 76.33(1)(a)1- POOL BASIN BRUSHED, VACUUMED

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 0.16 ppm.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      CLOSING CRITERIA-NO FUNCTIONAL EMERGENCY PHONE

      The Responsible Supervisor or operator has not closed the pool due to a nonfunctional emergency phone.

      Correction: Close the pool in the event of a nonfunctional emergency phone.

      Code ATCP 76.30 (1)(g) - FUNCTIONAL EMERGENCY PHONE

  4. Jul 23, 2024 Routine · 1 critical, 7 non-critical
    • Not serious Non-critical

      DOORS

      The door to the pump room/chemical storage is in need of repair due to excessive corrosion.

      Correction: Please repair and maintain pool pump door in accordance with recognized safe practices.

      Code ATCP 76.12 (2)(i) - DOORS

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical

      BIOHAZARD KIT-AVAILABLE

      A biohazard kit is not available.

      Correction: Provide a biohazard kit for the pool.

      Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Not serious Non-critical

      VGBA DRAIN COVER INFO-LIFESPAN

      The VGBA log or other proof does not indicate drain cover life span.

      Correction: Indicate in the log the drain cover life span.

      Code ATCP 76.38(2)(b)4. - LIFESPAN

    • Serious Critical

      INTERLOCK LOG-INFORMATION

      The monthly testing log is missing.

      Correction: Maintain a log that is documented with the date, results, and the name of the person performing the interlock test.

      Code ATCP 76.13 (1)(c)4.a - INTERLOCK LOG, INFORMATION REQUIRED

  5. Jul 19, 2023 Follow Up · 3 critical, 3 repeat
    • Serious Critical Repeat

      IN NEED OF REPAIR

      The equipment door to access the pool area is in significant need of repair.

      Correction: Please repair and maintain in accordance with recognized safe practices.

      Code ATCP 76.37(1)(a)

    • Serious Critical Repeat

      WORN PARTS NEEDING REPLACEMENT

      Chemical Feeders/Pumps in the equipment room is in need of monitoring and quality check.

      Correction: Please have contracted company come out and ensure that feeders/pumps are working correctly to ensure that pool maintains properly balanced.

      Code ATCP 76.37(1)(c)

    • Serious Critical Repeat

      CHLORINE TOO LOW

      The chlorine residual was <1ppm at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual to between 1-10ppm and contact Health Department before re-opening.

      Code [A] ATCP 76.14(4)(a)

  6. Jul 18, 2023 Routine · 3 critical
    • Serious Critical

      IN NEED OF REPAIR

      The equipment door to access the pool area is in significant need of repair.

      Correction: Please repair and maintain in accordance with recognized safe practices.

      Code ATCP 76.37(1)(a)

    • Serious Critical

      WORN PARTS NEEDING REPLACEMENT

      Chemical Feeders/Pumps in the equipment room is in need of monitoring and quality check.

      Correction: Please have contracted company come out and ensure that feeders/pumps are working correctly to ensure that pool maintains properly balanced.

      Code ATCP 76.37(1)(c)

    • Serious Critical

      CHLORINE TOO LOW

      The chlorine residual was <1ppm at the time of the inspection.

      Correction: Close the pool and raise the chlorine residual to between 1-10ppm and contact Health Department before re-opening.

      Code [A] ATCP 76.14(4)(a)

Source: City of Wauwatosa Health Department. History last read Oct 22, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.