Normandy Village Pool
2562 N 124 ST, Wauwatosa, WI 53226 · Milwaukee County
Establishment
- Type
- Pool / recreational water (Swimming)
- Inspected by
- City of Wauwatosa Health Department
- License / ID
- CAMN-CGJPEK
- Status
- Permitted
- Official record
- City of Wauwatosa Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 0 | 0 |
| 2025 | 2 | 6 | 2 |
| 2024 | 1 | 8 | 1 |
| 2023 | 2 | 6 | 6 |
Inspections
-
Jun 29, 2026 Routine · No items found
No violations cited.
-
Jul 9, 2025 Re-inspection · No items found
No violations cited.
-
Jul 8, 2025 Routine · 2 critical, 4 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition. It is not reading the flow.
Correction: Adjust or repair the [ ].
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 625 mV.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
POSTING SIGNAGE-SUPERVISION OF CHILDREN
At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present.
Correction: Post signage stating that children under 12 must be supervised.
Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN
-
Not serious
Non-critical
POOL BASIN ROUTINELY BRUSHED, VACUUMED
Pool basin is not routinely brushed or vacuumed to keep the basin and surrounding appurtenances free of sediment and debris.
Correction: Routinely brush or vacuum the pool basin to keep the basin and surrounding appurtenances free of sediment, lint, hair, debris, algae, and slime growth and discoloration.
Code ATCP 76.33(1)(a)1- POOL BASIN BRUSHED, VACUUMED
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 0.16 ppm.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
CLOSING CRITERIA-NO FUNCTIONAL EMERGENCY PHONE
The Responsible Supervisor or operator has not closed the pool due to a nonfunctional emergency phone.
Correction: Close the pool in the event of a nonfunctional emergency phone.
Code ATCP 76.30 (1)(g) - FUNCTIONAL EMERGENCY PHONE
-
Not serious
Non-critical
-
Jul 23, 2024 Routine · 1 critical, 7 non-critical
-
Not serious
Non-critical
DOORS
The door to the pump room/chemical storage is in need of repair due to excessive corrosion.
Correction: Please repair and maintain pool pump door in accordance with recognized safe practices.
Code ATCP 76.12 (2)(i) - DOORS
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Not serious
Non-critical
VGBA DRAIN COVER INFO-LIFESPAN
The VGBA log or other proof does not indicate drain cover life span.
Correction: Indicate in the log the drain cover life span.
Code ATCP 76.38(2)(b)4. - LIFESPAN
-
Serious
Critical
INTERLOCK LOG-INFORMATION
The monthly testing log is missing.
Correction: Maintain a log that is documented with the date, results, and the name of the person performing the interlock test.
Code ATCP 76.13 (1)(c)4.a - INTERLOCK LOG, INFORMATION REQUIRED
-
Not serious
Non-critical
-
Jul 19, 2023 Follow Up · 3 critical, 3 repeat
-
Serious
Critical
Repeat
IN NEED OF REPAIR
The equipment door to access the pool area is in significant need of repair.
Correction: Please repair and maintain in accordance with recognized safe practices.
Code ATCP 76.37(1)(a)
-
Serious
Critical
Repeat
WORN PARTS NEEDING REPLACEMENT
Chemical Feeders/Pumps in the equipment room is in need of monitoring and quality check.
Correction: Please have contracted company come out and ensure that feeders/pumps are working correctly to ensure that pool maintains properly balanced.
Code ATCP 76.37(1)(c)
-
Serious
Critical
Repeat
CHLORINE TOO LOW
The chlorine residual was <1ppm at the time of the inspection.
Correction: Close the pool and raise the chlorine residual to between 1-10ppm and contact Health Department before re-opening.
Code [A] ATCP 76.14(4)(a)
-
Serious
Critical
Repeat
-
Jul 18, 2023 Routine · 3 critical
-
Serious
Critical
IN NEED OF REPAIR
The equipment door to access the pool area is in significant need of repair.
Correction: Please repair and maintain in accordance with recognized safe practices.
Code ATCP 76.37(1)(a)
-
Serious
Critical
WORN PARTS NEEDING REPLACEMENT
Chemical Feeders/Pumps in the equipment room is in need of monitoring and quality check.
Correction: Please have contracted company come out and ensure that feeders/pumps are working correctly to ensure that pool maintains properly balanced.
Code ATCP 76.37(1)(c)
-
Serious
Critical
CHLORINE TOO LOW
The chlorine residual was <1ppm at the time of the inspection.
Correction: Close the pool and raise the chlorine residual to between 1-10ppm and contact Health Department before re-opening.
Code [A] ATCP 76.14(4)(a)
-
Serious
Critical
Source: City of Wauwatosa Health Department. History last read Oct 22, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.