Serafino Square Apartments Pool
9993 W NORTH AVE, Wauwatosa, WI 53226 · Milwaukee County
Establishment
- Type
- Pool / recreational water (Swimming)
- Inspected by
- City of Wauwatosa Health Department
- License / ID
- CHUS-AS2QCC
- Status
- Permitted
- Phone
- (414) 771-4918
- Official record
- City of Wauwatosa Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 4 | 2 |
| 2025 | 2 | 9 | 1 |
| 2024 | 1 | 6 | 1 |
| 2023 | 1 | 0 | 0 |
Inspections
-
May 27, 2026 Routine · 2 critical, 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE-SUPERVISION OF CHILDREN
At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present.
Correction: Post signage stating that children under 12 must be supervised.
Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load is not posted.
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 0.85 ppm for Free Chlorine.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. Needs to be between 1 ppm - 10 ppm.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Corrected on site
CLOSING CRITERIA-NO FUNCTIONAL EMERGENCY PHONE
The emergency phone is nonfunctional. *Corrected during the inspection.
Correction: Close the pool in the event of a nonfunctional emergency phone.
Code ATCP 76.30 (1)(g) - FUNCTIONAL EMERGENCY PHONE
-
Not serious
Non-critical
Repeat
-
Jul 21, 2025 Follow Up · No items found
No violations cited.
-
Jul 1, 2025 Routine · 1 critical, 8 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. The following are pasted the BBD: R-004 (10/21), R-0013 (6/23), R-0870 (6/24), list is not all inclusive.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
MAX PATRON LOAD POOL
The Max Patron Load is not posted. (The number has faded completely off)
Correction: Calculate the maximum patron load to provide at least 15 square feet per patron in the shallow portion and 25 square feet per patron in the deep portion and do not allow maximum patron load to be exceeded.
Code ATCP 76.25(2)(a) - POOL
-
Not serious
Non-critical
POSTING SIGNAGE-SUPERVISION OF CHILDREN
No signage stating that children under 12 must be supervised.
Correction: Post signage stating that children under 12 must be supervised.
Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN
-
Not serious
Non-critical
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load is not posted. The number has faded off completely.
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
POOL BASIN ROUTINELY BRUSHED, VACUUMED
Pool basin is not routinely brushed or vacuumed to keep the basin and surrounding appurtenances free of sediment, leaves, lint, hair, debris, algae, and slime growth and discoloration.
Correction: Routinely brush or vacuum the pool basin to keep the basin and surrounding appurtenances free of sediment, lint, hair, debris, algae, and slime growth and discoloration.
Code ATCP 76.33(1)(a)1- POOL BASIN BRUSHED, VACUUMED
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The entrance ladder on the east side of the pool is loose.
Correction: Maintain the pool equipment.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a VGBA log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement and installation such as invoices and specification sheets.
Correction: Maintain a log that can be used to evaluate the drain covers and keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Not serious
Non-critical
Repeat
-
Jul 22, 2024 Routine · 1 critical, 5 non-critical
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
REAGENTS REPLACED
Various test kit reagents observed not replaced as recommended by the manufacturer's best by date. Kit reagents observed from 2019,2021, etc.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
TELEPHONE-EMERGENCY NUMBERS AND ADDRESS
A list of emergency numbers and facility address not attached or posted near telephone.
Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.
Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. .
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make, model and life span of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
INTERLOCK LOG-INFORMATION
The monthly testing log for the interlock is not being incomplete.
Correction: Maintain a log that is documented with the date, results, and the name of the person performing the interlock test. *A template including interlock tests was emailed on 7/10/24. Please ensure monthly checks are being documented and that you have everything up to date by your next routine inspection.
Code ATCP 76.13 (1)(c)4.a - INTERLOCK LOG, INFORMATION REQUIRED
-
Not serious
Non-critical
-
Jun 22, 2023 Routine · No items found
No violations cited.
Source: City of Wauwatosa Health Department. History last read Oct 22, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.