Inspections
-
Oct 27, 2026 Routine · 2 critical, 8 non-critical, 2 repeat
-
Not serious
Non-critical
ELECTRONIC MONITORING FREQUENCY OF TESTING
The Spa, with an electronic monitoring device, has not been manually tested at least once a day with an approved test kit for pH and disinfectant/sanitizer residual.
Correction: Manually test the pool at least once a day for pH and disinfectant or sanitizer residual with an approved test kit and log the chemistry daily. The chemistry logs must be kept on file for 2 years.
Code ATCP 76.18(3)(a) - ELECTRONIC MONITORING TEST FREQ
-
Not serious
Non-critical
SIGNAGE 'NO LIFEGUARD ON DUTY'
A pool not required to have a lifeguard, does not have a 'no lifeguard on duty' sign.
Correction: Provide a sign to indicate 'no lifeguard on duty.'
Code ATCP 76.23(2)- NO LIFEGUARD ON DUTY
-
Not serious
Non-critical
TELEPHONE-EMERGENCY NUMBERS AND ADDRESS
The facility address not attached or posted near telephone.
Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.
Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED
-
Not serious
Non-critical
POOL RULES SIGNAGE- COMMUNICABLE DISEASE
Pool rules missing rules 1. Do not enter the pool if you have a communicable disease or an open cut. 2. Glass and shatterable items are prohibited in the pool area. 3. Do not bring animals into the pool area. 4. Do not run or engage in rough play in the pool area.
Correction: The signage in the whirlpool area must also include the applicable general pool rules under ATCP 76.29(1), including: Do not enter the pool if you have a communicable disease or an open cut. Do not bring food, drink, gum, or tobacco into the pool. Shower immediately before entering the pool and after using a steam room, sauna, or toilet facilities. Do not run or engage in rough play in the pool ar
Code ATCP 76.29(1)(b)1.a - NO COMMUNICABLE DISEASE, OPEN CUT
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
WHIRLPOOLS-SIGNAGE POSTED
The word WARNING preceding the five whirlpool-specific warnings must be at least 1 inch high.
Correction: Post the rule for the whirlpool. WARNING — WHIRLPOOL RULES 1. Persons suffering from heart disease, diabetes, or high or low blood pressure should consult their physician before using a whirlpool. 2. Persons under the influence of alcohol or drugs may not use the whirlpool. 3. Pregnant women should consult their physician regarding whirlpool usage. 4. Lengthy exposure may be hazardous to your heal
Code ATCP 76.29(3) - WHIRLPOOL RULES POSTED
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-PUMP CURVE
The manufacturer’s pump performance curve diagram was not permanently maintained on premises:
Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.
Code ATCP 76.32(3)(a)3. - PUMP CURVE
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
Repeat
Corrected on site
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 3 ppm for Whirlpools/Spas. The Free Chlorine level was at 0.99 ppm at the time of the inspection. *Corrected during inspection: Free Chlorine levels were increased to 9.25 PPM.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.
Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Not serious
Non-critical
-
Oct 8, 2025 Re-inspection · 2 non-critical, 1 repeat
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-PUMP CURVE
The manufacturer’s pump performance curve diagram was not permanently maintained on premises:
Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.
Code ATCP 76.32(3)(a)3. - PUMP CURVE
-
Not serious
Non-critical
Repeat
VGBA DRAIN COVER INFO-INSTALLATION DATE
The VGBA log or other proof does not indicate drain cover installation date.
Correction: Indicate in the log of drain cover installation date.
Code ATCP 76.38(2)(b)5. - INSTALL DATE
-
Not serious
Non-critical
-
Sep 3, 2025 Routine · 1 critical, 5 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 189 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. Current reagents have the following dates 4/2025, 5/2025 and 9/2024.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-PUMP CURVE
The manufacturer’s pump performance curve diagram was not permanently maintained on premises:
Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.
Code ATCP 76.32(3)(a)3. - PUMP CURVE
-
Not serious
Non-critical
FILES RETAINED 2 YEARS-DAILY INSPECTIONS AND OPERATIONAL TESTS
Daily inspection and operational tests records not maintained on premises for 2 years.
Correction: Maintain on premises for 2 years reports of daily inspections and operational tests.
Code ATCP 76.32(3)(b)4. - DAILY INSPECTION AND OPERATIONAL TESTS
-
Not serious
Non-critical
VGBA DRAIN COVER INFO-INSTALLATION DATE
The VGBA log or other proof does not indicate drain cover installation date.
Correction: Indicate in the log of drain cover installation date.
Code ATCP 76.38(2)(b)5. - INSTALL DATE
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum sanitizer level is 3.0 ppm for whirlpool. Free chlorine observed at 2.38 ppm.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Not serious
Non-critical
Repeat
-
Aug 27, 2024 Routine · 1 critical, 4 non-critical
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 197 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
The whirlpool is not tested daily for free chlorine.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
The whirlpool is not tested at least twice a week for the combined chlorine level.
Correction: Test whirlpool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Not serious
Non-critical
POOL EQUIPMENT-REPAIRED AS NECESSARY
The pipe following the pool's pump is leaking with water that falling into a catch bucket.
Correction: The pool equipment is not repaired as necessary.
Code ATCP 76.33(1)(e)4. - EQPT REPAIRED AS NEEDED
-
Serious
Critical
CHEMICAL STORAGE ACCESS RESTRICTED
Chemical storage area access not restricted to authorized personnel from the Men's Locker Room.
Correction: Restrict access to chemical storage area to only authorized personnel.
Code ATCP 76.12 (2)(d) - ACCESS RESTRICTED
-
Not serious
Non-critical
-
Sep 19, 2023 Routine · 1 non-critical
-
Not serious
Non-critical
MAXIMUM PATRON LOAD NOT POSTED
The maximum patron load is not posted in the facility.
Correction: Post the maximum patron load in accordance with ATCP 76.29(1)(d).
Code [A] ATCP 76.29(1)(d)
-
Not serious
Non-critical
Source: City of Wauwatosa Health Department. History last read Nov 14, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.