RecordWell Data

2929 On Mayfair Pool

2929 N MAYFAIR RD, Wauwatosa, WI 53222 · Milwaukee County

19cited violations
8serious tier
6inspections

Establishment

Type
Pool / recreational water (Swimming)
Inspected by
City of Wauwatosa Health Department
License / ID
OFER-CTTS4F
Status
Permitted
Phone
(608) 509-5345
Official record
City of Wauwatosa Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20262137
2025100
2024141
2023220

Inspections

  1. Jun 25, 2026 Re-inspection · 1 critical, 3 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      TEST KIT APPROVED

      The Taylor Pool Kit's reagents are expired (2/2026).

      Correction: Replace the approved pool kit.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical Repeat

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical Repeat

      POSTING SIGNAGE-SUPERVISION OF CHILDREN

      At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present.

      Correction: Post signage stating that children under 12 must be supervised.

      Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN

    • Serious Critical Repeat

      RING BOUY

      The rope is not attached to the ring buoy.

      Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.

      Code ATCP 76.26(1)(b)2.a - RING BOUY

  2. Jun 22, 2026 Routine · 6 critical, 3 non-critical, 2 repeat
    • Not serious Non-critical

      TEST KIT APPROVED

      The Taylor Pool Kit's reagents are expired (2/2026).

      Correction: Replace the approved pool kit.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical Repeat

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical Repeat

      POSTING SIGNAGE-SUPERVISION OF CHILDREN

      At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present.

      Correction: Post signage stating that children under 12 must be supervised.

      Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN

    • Serious Critical

      RECIRCULATION SYSTEM CONTINUOUS OPERATION

      The pool recirculation system is not continuously operated. Due to a faulty valve the pool pump has been shut off periodically to allow the pool to drain and not overfill.

      Correction: The pool must be closed immediately until the recirculation system is in place and in continuous operation.

      Code ATCP 76.11(1) - RECIRCULATION SYSTEM PRESENT, CONTINUOUSLY O

    • Serious Critical

      EVACUATION WHEN RECIRCULATION INTERRUPTED

      Recirculation flow has been interrupted and patrons were not evacuated from pool or pool closed.

      Correction: Ensure that anytime the recirculation flow is interrupted, patrons are instructed to evacuate the pool. Keep the pool closed until the system is restored to proper operation and chemical levels.

      Code ATCP 76.13(4) - EVACUATION WHEN RECIRCULATION INTERRUPTED

    • Serious Critical

      PH

      The pH is 7.95.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical

      RING BOUY

      The rope is not attached to the ring buoy.

      Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.

      Code ATCP 76.26(1)(b)2.a - RING BOUY

    • Serious Critical

      CLOSING CRITERIA-FAILURE TO MEET 76.16

      The Responsible Supervisor or operator has not closed the pool after failure to comply with the water quality requirements. Free chlorine level observed at 0.33 ppm.

      Correction: Close the pool in the event of failure to comply with the water quality requirements pursuant to s. ATCP 76.16.

      Code ATCP 76.30 (1)(b) - FAILURE TO MEET ATCP 76.16

    • Serious Critical

      CLOSING CRITERIA-NO FUNCTIONAL EMERGENCY PHONE

      The Responsible Supervisor or operator has not closed the pool due to a nonfunctional emergency phone.

      Correction: Close the pool in the event of a nonfunctional emergency phone.

      Code ATCP 76.30 (1)(g) - FUNCTIONAL EMERGENCY PHONE

  3. Jul 9, 2025 Routine · No items found

    No violations cited.

  4. Jun 21, 2024 Routine · 1 critical, 3 non-critical
    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      BIOHAZARD KIT-AVAILABLE

      A biohazard kit is not available.

      Correction: Provide a biohazard kit for the pool.

      Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover. VGBA Log emailed to operator - Please fill in information to provide for next inspection.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical

      PH

      The pH was at 7.90 and decreased to 7.86 roughly 20 minutes later.

      Correction: Please retest the pool in the afternoon to ensure pH continued to drop back within range. Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

  5. Sep 20, 2023 Routine · 1 non-critical
    • Not serious Non-critical

      ALKALINITY OUT OF BALANCE

      The total alkalinity is 55.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

  6. Aug 9, 2023 Pre-inspection · 1 non-critical
    • Not serious Non-critical

      MISSING RESCUE EQUIPMENT

      A ring buoy w/rope attachment is missing from the facility.

      Correction: Please provide a ring buoy w/rope attachment for the facility and mount it in a conspicuous location.

      Code ATCP 76.26(1)(b)

Source: City of Wauwatosa Health Department. History last read Oct 22, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.