Sleep Inn
1600 LAWRENCE DR, De Pere, WI 54115 · Brown County
Establishment
- Type
- Pool / recreational water (Whirlpool)
- Inspected by
- De Pere Health Department
- License / ID
- KBUE-C7QL7J
- Status
- Permitted
- Phone
- (920) 351-4126
- Official record
- De Pere Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 3 | 0 |
| 2025 | 2 | 5 | 1 |
| 2024 | 2 | 9 | 2 |
| 2023 | 1 | 5 | 1 |
Inspections
-
Aug 25, 2026 Routine · 3 non-critical, 1 repeat
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. The pH Exact test strip is expired.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-CHEMICAL TESTING
The operator did not record the following on the operating report: Results for chemical testing the last 3 days.
Correction: Record the following on the operating report, results for chemical testing.
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Not serious
Non-critical
-
Aug 28, 2025 Follow Up · No items found
No violations cited.
-
Aug 13, 2025 Routine · 1 critical, 4 non-critical, 2 repeat
-
Not serious
Non-critical
LABEL, CONSPICUOUS
Chemical containers of acid are not conspicuously labeled. Labels are not provided.
Correction: Provide a conspicuous, easily visible and read label on the chemical container.
Code ATCP 76.12 (1)(a)
-
Not serious
Non-critical
Repeat
SAFETY DATA SHEET
A safety data sheet was not available for powder chlorine for the new erosion feeder.
Correction: Maintain a safety data sheet for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
Repeat
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept. Monthly testing hasn't been documented since December 2024.
Correction: Keep a log of monthly interlock tests. Immediately begin conducting the monthly interlock tests and document this on the Log.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
OPERATING REPORTS-CHEMICAL TESTING
The operator did not record the following on the operating report: Results for chemical testing. Nothing documented since August 6th.
Correction: Record the following on the operating report, results for chemical testing, on a daily basis.
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant level is 0ppm for chlorine.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. Upon arrival, staff stated that the pool was closed due to a pump problem, but there was no signage indicating the whirlpool was closed. Staff instructed to place a sign on the door until repairs are made and the chlorine level is measured at a minimum of 3ppm.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Not serious
Non-critical
-
Aug 14, 2024 Follow Up · No items found
No violations cited.
-
Jul 31, 2024 Routine · 2 critical, 7 non-critical
-
Not serious
Non-critical
SAFETY DATA SHEET
A safety data sheet was not available for liquid chlorine and acid in the pool area.
Correction: Maintain a safety data sheet for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in the whirlpool and water is not tested daily for the combined chlorine level.
Correction: Test whirlpool water at least once daily for the combined chlorine level.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Not serious
Non-critical
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
EMERGENCY BLANKETS
Two emergency blankets in good condition are not available in the pool area.
Correction: Provide two emergency blankets in good condition in the pool area.
Code ATCP 76.27(3) - EMERGENCY BLANKETS
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Serious
Critical
OPERATOR KNOWLEDGE SAFETY DURING MONTHLY TESTING
The person responsible is not able to describe what safety measures that must be employed during monthly testing. The Responsible Supervisor was not present during the inspection.
Correction: Ensure that operator can describe what safety measures that must be employed during monthly testing.
Code ATCP 76.13 (1)(c)2.e -MONTHLY TESTING SAFETY
-
Serious
Critical
TELEPHONE ACCESSIBLE
The emergency telephone directly connects to the front desk rather then to emergency services. When picked up, the phone connects to the front desk where an attendant answers.
Correction: Provide a telephone capable of connecting with emergency services either by dial or direct connection.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Not serious
Non-critical
-
Nov 1, 2023 Routine · 1 critical, 4 non-critical
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 40ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. All reagents were observed expired.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in the whirlpool and the water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY
Whirlpool water not tested at least once a week for total alkalinity.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY
-
Serious
Critical
PH
The pH is 7.1.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Not serious
Non-critical
Source: De Pere Health Department. History last read Oct 22, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.