River Park Terrace Apartments
1901 RIDGEWAY DR, De Pere, WI 54115 · Brown County
Establishment
- Type
- Pool / recreational water (Whirlpool)
- Inspected by
- De Pere Health Department
- License / ID
- HSAT-7QXND9
- Status
- Permitted
- Phone
- (920) 337-9388
- Official record
- De Pere Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2025 | 1 | 4 | 1 |
| 2024 | 2 | 3 | 2 |
Inspections
-
Dec 18, 2025 Routine · 1 critical, 3 non-critical
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. pH and alkalinity reagents are expired.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
THERMOMETER RETURN LINE
A thermometer could not be located in the pool water return line.
Correction: Provide an accurate thermometer in the pool water return line.
Code ATCP 76.19(4)(a)1 - THERMOMETER
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Serious
Critical
INTERLOCK LOG-INFORMATION
The monthly testing of the interlock is not being documented on the pool logs.
Correction: Maintain a log that is documented with the date, results, and the name of the person performing the interlock test.
Code ATCP 76.13 (1)(c)4.a - INTERLOCK LOG, INFORMATION REQUIRED
-
Not serious
Non-critical
-
Dec 16, 2024 Routine · 2 critical, 1 non-critical
-
Not serious
Non-critical
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments. The old report is still being used.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant was less than 4ppm for bromine.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. The whirlpool was closed by the operator and began draining it due to low bromine and cloudiness.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
TELEPHONE ACCESSIBLE
The emergency phone is not working properly. There was loud static on the line making the dial tone unaudible.
Correction: Provide a working telephone or other technology capable of connecting with emergency services. Maintain the whirlpool closed until the phone is repaired.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Not serious
Non-critical
-
Feb 9, 2024 Routine · No items found
No violations cited.
Source: De Pere Health Department. History last read Oct 22, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.