RecordWell Data

Ruhnke Cabin

7465 W CARA LN, Medford, WI 54451 · Taylor County

4cited violations
2serious tier
3inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Taylor County Health Department
License / ID
MCAN-CZCVTL
Status
Permitted
Phone
(815) 236-6600
Official record
Taylor County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026100
2025100
2024142

Inspections

  1. May 11, 2026 Routine · No items found

    No violations cited.

  2. May 30, 2025 Routine · No items found

    No violations cited.

  3. Jun 4, 2024 Routine · 2 critical, 2 non-critical
    • Not serious Non-critical

      SPACE HEATERS – VENTILATION REQUIREMENT

      Space heater installation (in the garage, accessible to guests) does not provide a constant source of fresh air.

      Correction: Provide a constant source of fresh air through a permanent opening. Or restrict access to guests.

      Code ATCP 72.14 (2) (a)

    • Not serious Non-critical

      GENERAL MAINTENANCE

      Move bench and table away from railing on rear deck. Enclose exposed electrical wires on posts leading to the waterfront. Repair doorbell button at front entrance.

      Correction: Maintain establishment in a manner conducive to the health, comfort and safety of its guests.

      Code [C] ATCP 72.15 (1)

    • Serious Critical

      PLUMBING CROSS-CONNECTIONS

      The following cross-connections have been identified: Threaded terminal ends on the faucet of the point well in the garage and the outdoor spiggots.

      Correction: Provide an air gap or other approved backflow/backsiphonage protection device.

      Code [A] ATCP 72.10 (4)

    • Serious Critical

      CARBON MONOXIDE DETECTORS - REQUIREMENT

      A carbon monoxide detector is not provided [in units, outside of each separate sleeping area (identify area) in the immediate vicinity of the sleeping rooms and/or in sleeping rooms, where a fuel-burning appliance is located]. One carbon monoxide detector is located in the main hallway on the main floor.

      Correction: Provide carbon monoxide detectors in all required locations.

      Code [A] ATCP 72.145 (3)

Source: Taylor County Health Department. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.