Badger Market (medical Science Center)
1300 UNIVERSITY, Madison, WI 53706 · Dane County
Establishment
- Type
- Retail food (not serving meals) (Retail Food - Not Serving Meals, Moderate)
- Inspected by
- University Environmental Health Program
- License / ID
- BWER-9KHN5W
- Status
- Permitted
- Phone
- (608) 263-2543
- Official record
- University Environmental Health Program inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 4 | 9 | 2 |
| 2025 | 3 | 2 | 1 |
| 2024 | 3 | 13 | 3 |
Inspections
-
Oct 19, 2026 Re-inspection · No items found
No violations cited.
-
Oct 19, 2026 Re-inspection · No items found
No violations cited.
-
Oct 6, 2026 Routine · 1 priority, 1 priority foundation, 3 core, 2 repeat
-
Serious
Priority
Repeat
Corrected on site
TCS FOOD - COLD HOLDING
Salmon Stackers in reach in display cooler were cold held at 45°F. Product was removed and discarded. No TCS product will be placed in the cooler until it is repaired.
Correction: Maintain cold time/temperature control for safety food at or below 41°F. Discard unsafe food items.
Code 3-501.16 (A) (2) AND (B)
-
Not serious
Priority Foundation
CONTROLLING PESTS - TRAPPING DEVICES
Evidence of mice observed. A live mouse was seen earlier in the day and droppings were observed in several areas, including up from under the register and in the back storage area. Provide for droppings to be cleaned up and work with PCO to remove pests from the facility.
Correction: Eliminate pests or insects from food establishment. It is recommended that you work with a professional pest control company. Discard any potentially contaminated food or single-use items and clean and sanitize potentially affected equipment.
Code 6-501.111 (C)
-
Not serious
Core
Corrected on site
PROPER COOLING METHODS - IN EQUIPMENT
Tightly covered rice was observed actively cooling in its commercial packaging. Foods should remain uncovered or loosely covered during the cooling process to facilitate rapid cooling to 41°F. The rice was removed from the commercial packaging, transferred to a secondary food container, and left uncovered to continue cooling.
Correction: Provide containers that facilitate heat transfer, such as metal pans, and loosely cover food items during the cooling process so that heat is allowed to escape.
Code 3-501.15 (B)
-
Not serious
Core
Repeat
EQUIPMENT AND UTENSILS - GOOD REPAIR
Two coolers were observed in need of repair. The doors on the self-service cooler located on the left side of the retail area were not closing securely, and the door gaskets were in need of repair. In addition, the self-service reach-in cooler at Naan Stop was not maintaining proper temperature. The ambient temperature of the cooler was measured at 47°F. Work orders for both units were submitted during the inspection.
Correction: Repair equipment to good condition or remove from premise.
Code 4-501.11 (A)
-
Not serious
Core
CLEANING, FREQUENCY AND RESTRICTIONS
The floors under equipment and at floor/wall junctures are in need of cleaning. Provide for equipment to be moved out from wall to properly clean underneath.
Correction: Clean the physical facilities at a frequency necessary to keep them clean.
Code 6-501.12
-
Serious
Priority
Repeat
Corrected on site
-
Apr 30, 2026 Routine · 1 priority, 1 priority foundation, 2 core
-
Serious
Priority
Corrected on site
TCS FOOD - COLD HOLDING
The True 1 door cooler int he coffee area was not holding temperature and the milk and creamer inside was found at 46F. Ambient of cooler was 45F. Product was removed and discarded.
Correction: Maintain cold time/temperature control for safety food at or below 41°F. Discard unsafe food items.
Code 3-501.16 (A) (2) AND (B)
-
Not serious
Priority Foundation
Corrected on site
DEMONSTRATION OF KNOWLEDGE - ILLNESS REPORTING RESPONSIBILITES
The student person in charge is unable to demonstrate knowledge regarding foodborne illness reporting requirements by employees. I did a little onsite training with the student person in charge and discussed symptom and illness reporting requirements.
Correction: Obtain training on foodborne illness signs and symptoms and provide training to employees regarding their responsibility in reporting foodborne illness signs and symptoms to the person in charge.
Code 2-102.11 (C) (17)
-
Not serious
Core
Corrected on site
PERSONAL CLEANLINESS - HAIR RESTRAINTS
Employee noted working in food preparation/cooking area without a hair restraint. Student corrected by putting on hat.
Correction: Provide employees working in food preparation and cooking areas with effective hair restraint (hat, hair net, beard restraint, etc.).
Code 2-402.11
-
Not serious
Core
Corrected on site
EQUIPMENT AND UTENSILS - GOOD REPAIR
True 1 door cooler is not maintained in good repair. Ambient temperature was 45F and TCS product inside had to be discarded. Provide for this cooler to be repaired or only store non TCS items in the cooler. Current plan is to place milk and creamer in back storage area and only keep non TCS items in the cooler.
Correction: Repair equipment to good condition or remove from premise.
Code 4-501.11 (A)
-
Serious
Priority
Corrected on site
-
Sep 9, 2025 Routine · No items found
No violations cited.
-
Apr 25, 2025 Re-inspection · No items found
No violations cited.
-
Apr 18, 2025 Routine · 1 priority, 1 core, 1 repeat
-
Serious
Priority
TCS FOOD - COLD HOLDING
The True 1-Door cooler (45°F ambient) behind the beverage counter is not keeping TCS food items at 41°F or below. The following food temperatures were recorded from this cooler: Half and Half Carafe-47°F, Whole Milk-46°F, Skim Milk-45°F. A jug of whole milk that was recently transferred from the True 1-Door cooler to the Under Counter Milk Cooler was at 45°F. The person in charge voluntarily discarded all TCS food items from the True 1-Door Cooler during the inspection. They stated they will put in a work order to have the cooler serviced.
Correction: Maintain cold time/temperature control for safety food at or below 41°F. Discard unsafe food items.
Code 3-501.16 (A) (2) AND (B)
-
Not serious
Core
Repeat
REPAIRING - PREMISES, STRUCTURES, ATTACHMENTS, AND FIXTURES - METHODS
Ceiling tiles near the back of the storage room are heavily stained and show signs of water damage.
Correction: Maintain the physical facilities so they are in good repair at all times. Repair or replace stained and/or water logged ceiling tiles.
Code 6-501.11
-
Serious
Priority
-
Oct 11, 2024 Re-inspection · 1 core, 1 repeat
-
Not serious
Core
Repeat
REPAIRING - PREMISES, STRUCTURES, ATTACHMENTS, AND FIXTURES - METHODS
Ceiling tiles above the mop sink were noted with signs of water damage and staining.
Correction: Maintain the physical facilities so they are in good repair at all times. Clean or replace ceiling tiles.
Code 6-501.11
-
Not serious
Core
Repeat
-
Oct 8, 2024 Routine · 2 priority, 3 core, 1 repeat
-
Serious
Priority
Repeat
TCS FOOD - COLD HOLDING
Raita in the ice bath was at 49°F. Cheddar cheese chive scone and asiago cheddar bagels were being stored at room temperature.
Correction: The person in charge cooled the items down (as they were recently received) during the inspection. Discussed that raita condiment bottle shall be stored in direct contact with ice bath. Discussed that cheddar cheese scone/bagels shall be kept refrigerated. Maintain cold time/temperature control for safety food at or below 41°F.
Code 3-501.16 (A) (2) AND (B)
-
Serious
Priority
Corrected on site
PLUMBING - BACKFLOW PREVENTION - AIR GAP
The portable ice bin had a hose connected to its drainage spout with the hose stored inside a floor drain.
Correction: The person in charge removed the hose during the inspection.
Code 5-202.13
-
Not serious
Core
Corrected on site
OPEN DRINK CONTAINER
An open employee water bottle was stored next to the espresso drink equipment/on the food prep counter.
Correction: The beverage was moved to an approved space during the inspection.
Code 2-401.11 (B)
-
Not serious
Core
IN-USE UTENSILS, BETWEEN USE STORAGE
In use espresso drink utensils and steaming pitcher were stored on a damp towel.
Correction: Store in-use utensils on a clean surface. The person in charge noted that they have purchased drying mats.
Code 3-304.12
-
Not serious
Core
REPAIRING - PREMISES, STRUCTURES, ATTACHMENTS, AND FIXTURES - METHODS
Ceiling tiles above the mop sink were noted with signs of water damage and staining.
Correction: Maintain the physical facilities so they are in good repair at all times. Clean or replace ceiling tiles.
Code 6-501.11
-
Serious
Priority
Repeat
-
Mar 21, 2024 Routine · 1 priority, 2 priority foundation, 4 core
-
Serious
Priority
Corrected on site
TCS FOOD - COLD HOLDING
Jalapeno cheese bagels in bakery case are cold held at 72, 74°F.
Correction: Maintain cold time/temperature control for safety food at or below 41°F. Discard unsafe food items. Corrected during inspection. Two bagels voluntarily discarded.
Code 3-501.16 (A) (2) AND (B)
-
Not serious
Priority Foundation
THERMOMETERS - AMBIENT AIR AND WATER - ACCURACY
Thermometer used for measuring plate surface temperatures in dish machine is not functioning.
Correction: Provide new batteries or replace thermometer.
Code 4-203.12
-
Not serious
Priority Foundation
Corrected on site
HAND DRYING PROVISION
No single-use toweling or other hand drying device available at employee handwashing sink for hand drying.
Correction: Provide single-use toweling or other approved devices at employee handwashing sink to facilitate proper handwashing. Corrected during inspection. Paper towels stocked in dispenser.
Code 6-301.12
-
Not serious
Core
EQUIPMENT AND UTENSILS - GOOD REPAIR
Bagel slicer at customer self-serve area is not maintained in good repair. The base is cracked and missing a piece.
Correction: Repair equipment to good condition or remove from premise.
Code 4-501.11 (A)
-
Not serious
Core
SINGLE-USE AND SINGLE SERVICE ARTICLES - ORIGINAL CONTAINER
Clam shell containers stacked at sandwich station are stacked food-contact-side up and not protected again contamination.
Correction: Store single-use articles in their original container or use other effective means to prevent contamination such as storing clam shells food-contact-side down.
Code 4-903.11 (C)
-
Not serious
Core
REPAIRING - PREMISES, STRUCTURES, ATTACHMENTS, AND FIXTURES - METHODS
The lightshield located in the back prep area near the handwashing sink is cracked, is missing pieces, and is in disrepair,.
Correction: Maintain the physical facilities so they are in good repair at all times. Repair or replace lightshield. Operator placed work order during inspection.
Code 6-501.11
-
Not serious
Core
CLEANING, FREQUENCY AND RESTRICTIONS
The ceiling vents in the back prep area are soiled.
Correction: Clean the physical facilities at a frequency necessary to keep them clean. Clean ceiling vents. Operator placed work order during inspection.
Code 6-501.12
-
Serious
Priority
Corrected on site
Source: University Environmental Health Program. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.