RecordWell Data

Bradley & Jacqueline Bartel

981 LOON LAKE RD, Eagle River, WI 54521 · Vilas County

11cited violations
2serious tier
3inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Vilas County Public Health
License / ID
GSKK-D87KZ3
Status
Permitted
Phone
(920) 407-0017
Official record
Vilas County Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026182
2025130
2024100

Inspections

  1. Oct 27, 2026 Routine · 8 non-critical
    • Serious Critical

      Slip-resistant flooring in shower and bathtubs

      The shower is not provided with slip-resistant flooring or materials.

      Correction: Slip-resistant flooring or materials shall be provided in all shower and bathtub basins.

      Code ATCP 72.17(5)(f)

    • Serious Critical

      Bunk beds - guards not provided

      The upper bunk beds are not provided with permanently installed guards on the foot end of the bed

      Correction: Provide permanently installed guards on the upper bunk bed.

      Code ATCP 72.18(3)(d)4.

    • Not serious Priority Foundation

      Smoke alarm installed outside each separate sleeping area

      A smoke alarm is not provided outside of each separate sleeping area, within 21 feet of any door to a sleeping room. The hallway outside the back bedroom does not have a smoke alarm.

      Correction: Provide a smoke alarm outside of each separate sleeping area, within 21 feet of any door to a sleeping room.

      Code ATCP 72.18(11)(b)2.

    • Not serious Priority Foundation

      Smoke alarm installed in each sleeping room

      A smoke alarm is not within each sleeping room. One of the bedrooms does not have a smoke alarm.

      Correction: Provide a smoke alarm within each sleeping room.

      Code ATCP 72.18(11)(b)3.

    • Not serious Priority Foundation

      Carbon monoxide alarm installation - FBA outside IKU

      A carbon monoxide alarm is not provided outside of each separate sleeping area within the individually keyed units. A carbon monoxide alarm was missing from the hallway outside the back bedroom

      Correction: Provide carbon monoxide alarm outside of each separate sleeping area within the individually keyed units.

      Code ATCP 72.18(12)(c)

    • Not serious Priority Foundation

      Guard spacing <= 6"

      The spaces between guards on the spiral staircase are more than 6 inches.

      Correction: Modify the space between guards on the spiral staircase to be equal to or less than 6 inches.

      Code ATCP 72.18(2)(b)3.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

    • Not serious Non-critical

      License posted in public view

      A current license is not posted on the premises in a place visible to the public.

      Correction: Post a current license in the premises in a place visible to the public.

      Code ATCP 72.07(7)

  2. Aug 4, 2025 Routine · 3 non-critical
    • Not serious Non-critical

      PERMIT NOT DISPLAYED IN PUBLIC VIEW

      Permit is not displayed conspicuously to the public.

      Correction: Post the permit in a conspicuous location to the public as soon as possible.

      Code ATCP 72.04 (7)

    • Not serious Non-critical

      TOP BUNK-MISSING RAILS

      Both of the bunk beds in the loft area bedroom have no end structure guard railings at the foot of their beds.

      Correction: Install railings that are in compliance with 16 CFR 1513 as soon as possible.

      Code Wisconsin Statute 97.02

    • Not serious Non-critical

      GENERAL MAINTENANCE

      The spiral staircase leading up to the loft area has gaps in its guards exceeding the maximum length allowed of 6-inches.

      Correction: Install additional guards so that there are no gaps in space larger than 6-inches apart on this spiral staircase as soon as possible.

      Code [C] ATCP 72.15 (1)

  3. Aug 15, 2024 Pre-inspection · No items found

    No violations cited.

Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.