| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 14 | 2 |
| 2025 | 1 | 1 | 0 |
| 2024 | 1 | 3 | 2 |
| 2023 | 2 | 0 | 0 |
Inspections
-
Sep 1, 2026 Routine · 14 non-critical
-
Serious
Critical
Smoke alarm maintained - working order; expiration
The smoke alarm Nighthawk models in Forest Lodge have not been replaced in accordance with the manufacturer’s date of expiration (10 years).
Correction: Repair or replace the smoke alarm within 10 days. If more time is needed, please contact the department.
Code ATCP 72.18(11)(e)
-
Serious
Critical
Windows used for exiting - 20 inches x 24 inches
The Big Bear facility's sleeping areas in the basement have windows used for exiting has a window of 29 inches x 15 inches. The basement window opening does not meet code requirment. The basement does not contain 2 routes of egress
Correction: Provide a window opening at least 20 inches by 24 inches irrespective of the height or width, or provide a different exit, or discontinue sleeping from that floor. The operator shall discontinue using the basement as a sleeping area until sufficient egress windows are provided. Reminder: ATCP 72.18(4)(g) Windows used for exiting. A window used for exiting shall meet all of the following:5. If the
Code ATCP 72.18(4)(g)2.
-
Not serious
Priority Foundation
Smoke alarm installed outside each separate sleeping area
A smoke alarm is not provided outside of each separate sleeping area, within 21 feet of any door to a sleeping room in the Big Bear facility. The hallway outside of the sleeping rooms upstairs does not have a smoke alarm within the required distance.
Correction: Provide a smoke alarm outside of each separate sleeping area, within 21 feet of any door to a sleeping room.
Code ATCP 72.18(11)(b)2.
-
Not serious
Priority Foundation
Smoke alarm installed in each sleeping room
A smoke alarm is not within each sleeping room in the Big Bear facility. The sleeping room upstairs with the Brown trout picture does not have a smoke alarm.
Correction: Provide a smoke alarm within each sleeping room.
Code ATCP 72.18(11)(b)3.
-
Not serious
Priority Foundation
Carbon monoxide alarm installation - FBA outside IKU
A carbon monoxide alarm is not provided outside of the loft separate sleeping area and the sleeping room in the basement closest to cast iron wall hooks within the Forest Lodge facility.
Correction: Provide carbon monoxide alarm outside of each separate sleeping area within 21 feet.
Code ATCP 72.18(12)(c)
-
Not serious
Priority Foundation
Handrail on stairs height 30-38"
The height of the provided stair handrail leading to the Forest Lodge basement on the kitchen side of the facility is less than 30 inches measured vertically from the nose of the tread to the top of the handrail. The deck handrail on the Big Bear facility is less than 30 inches measured vertically from the nose of the tread to the top of the handrail.
Correction: Provide a stair handrail at a height between 30 to 38 inches measured vertically from the nose of the tread to the top of the handrail by next annual inspection.
Code ATCP 72.18(2)(a)2.
-
Not serious
Priority Foundation
Guards provided on stairs > 3 risers
Guards are not provided on all open sides on the top right side of the stairs leading to the loft. Guards are not provided on all open sides on the Forest Lodge front entry stairs.
Correction: Guards shall be provided on all open sides of stairs consisting of more than 3 risers by next annual inspection.
Code ATCP 72.18(2)(b)1.
-
Not serious
Priority Foundation
Guard spacing <= 6"
The space between multiple guards in the loft area is more than 6 inches. The corner of the loft near the PVC piping contains an open gap with no guards.
Correction: Modify the space between guards in the loft area to be equal to or less than 6 inches by next annual inspection.
Code ATCP 72.18(2)(b)3.
-
Not serious
Priority Foundation
Guard height >= 36" - elevated surfaces
The guard height is less than 36 inches on the Forest Lodge main floor stairs below the loft as measured vertically above the adjacent walking surface. The guard height is less than 36 inches on the deck on the Big Bear facility.
Correction: Modify the guard height to be equal to or greater than 36 inches on the main florr stairs below the loft as measured vertically above the adjacent walking surface by next annual inspection.
Code ATCP 72.18(2)(b)6.a.
-
Not serious
Priority Foundation
Bunk beds - 2.5' spacing between top bed and ceiling
A free space of less than 2.5 feet was observed above the mattress of the upper bunk beds in the Big Bear facility.
Correction: Provide a free space of at least 2.5 feet above the mattress of the upper bunk beds. The corrective action is not required until the Big Bear facility provides egress windows in the basement sleeping areas in accordance with ATCP 72.
Code ATCP 72.18(3)(d)3.
-
Not serious
Priority Foundation
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post the building evacuation diagram for each floor level in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Not serious
Non-critical
License posted in public view
A current license is not posted on the premises in a place visible to the public.
Correction: Post a current license in the premises in a place visible to the public.
Code ATCP 72.07(7)
-
Not serious
Non-critical
Smoke alarm UL certified or equivalent
The smoke alarm type installed throughout much of the Forest Lodge facility does not have the UL listing mark or a similar mark from an independent product safety certification organization. The identified smoke alarms have a CE-mark which is a mark used in the European Union which does not meet National Electric Code or is a Nationally Recognized testing laboratory.
Correction: Provide smoke alarms that have UL listing marks or a similar marks from an independent product safety certification organization.
Code ATCP 72.18(11)(c)
-
Not serious
Non-critical
Exterior of building maintained
The Big Bear facility is not maintained in good repair with paint peeling along the exterior walls and fascia boards. The Big Bear facility window sills have a built up of debris and insects. The Big Bear facility window screen on the back entry is damaged with holes and paper towels placed into the holes.
Correction: Maintain the exterior and interior of the building in good repair and clean condition.
Code ATCP 72.19(1)(c)1.
-
Serious
Critical
-
Jul 10, 2025 Routine · 1 non-critical
-
Not serious
Non-critical
GENERAL MAINTENANCE
The stairs leading up to the loft from the main floor have gaps in their guard spacing more than 6-inches apart. I measured at least one gap which was 10.5-inches in length.
Correction: Add additional guards on this staircase that are less than 6-inches maximum apart from one another, or add plexiglass to cover all of these these open gaps as soon as possible.
Code [C] ATCP 72.15 (1)
-
Not serious
Non-critical
-
Jul 19, 2024 Routine · 2 critical, 1 non-critical
-
Not serious
Non-critical
UTENSIL SANITIZATION - CLEANING PROCEDURES
Multi-use food contact surfaces, such as bowls and glassware are not being sanitized for different guests.
Correction: All multi-use utensils must be washed, rinsed and sanitized using approved methods, equipment and chemicals. Provide bleach in both Big Bear and Little Cub cabins to ensure guests can properly sanitize multi-use contact surfaces. Correct by next routine inspection.
Code [A] ATCP 72.11 (3)(a)
-
Serious
Critical
SMOKE DETECTORS - REQUIREMENT
Smoke detector in Little Cub Cabin is not in proper working order.
Correction: Replace smoke detector in cabin. Submit proof of a properly working smoke detector to staff.camaratoje86@uwosh.edu or (715)525-9804 by 7/26/2024.
Code ATCP 72.14 (2) (c)
-
Serious
Critical
CARBON MONOXIDE DETECTORS - REQUIREMENT
A carbon monoxide detector is not provided in Big Bear cabin.
Correction: Provide carbon monoxide detector in Big Bear cabin. Submit proof of installation to staff.camaratoje86@uwosh.edu or (715)525-9804 by 7/26/2024.
Code [A] ATCP 72.145 (3)
-
Not serious
Non-critical
-
Aug 5, 2023 Routine · No items found
No violations cited.
-
Jun 2, 2023 Routine · No items found
No violations cited.