RecordWell Data

Bear's Paw Resort

7538 SKYVIEW DR, Saint Germain, WI 54558 · Vilas County

15cited violations
5serious tier
4inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Vilas County Public Health
License / ID
TAYL-AMWJVE
Status
Permitted
Phone
(800) 445-5360
Official record
Vilas County Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20261125
2025120
2024110
2023100

Inspections

  1. Sep 10, 2026 Routine · 10 non-critical
    • Serious Critical

      Carbon monoxide alarms provided

      A carbon monoxide alarm is not provided anywhere in the additional building that also contains a fuel-burning appliance.

      Correction: Provide carbon monoxide alarms at the locations specified in rule.

      Code ATCP 72.18(12)(a)

    • Serious Critical

      Carbon monoxide alarm installation - FBA within IKU or sleeping room

      A carbon monoxide alarm is not provided in the porch/entrace with the wood fireplace. Futon placed in this area which can be used for sleeping.

      Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.

      Code ATCP 72.18(12)(b)

    • Serious Critical

      Carbon monoxide alarm installation - FBA within IKU or sleeping room

      A carbon monoxide alarm is not provided, outside of the sleeping area in the additional building.

      Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.

      Code ATCP 72.18(12)(b)

    • Serious Critical

      First floor sleeping room - 2 exits provided

      The first floor used for sleeping was not provided with at least 2 separate exits. Windows do not meet egress requirements.

      Correction: Provide at least 2 separate exits from the first floor used for sleeping or discontinue sleeping from that floor.

      Code ATCP 72.18(4)(b)

    • Serious Critical

      Windows used for exiting - 20 inches x 24 inches

      The additional building sleeping area windows used for exiting have window openings of 15"x25"

      Correction: Provide a window opening at least 20 inches by 24 inches irrespective of the height or width, or provide a different exit, or discontinue sleeping from that floor.

      Code ATCP 72.18(4)(g)2.

    • Not serious Priority Foundation

      Smoke alarm installed in each sleeping room

      A smoke alarm is not within each sleeping room. The additional building sleeping rooms do not have a smoke alarm.

      Correction: Provide a smoke alarm within each sleeping room.

      Code ATCP 72.18(11)(b)3.

    • Not serious Priority Foundation

      Smoke alarm installed in each sleeping room

      A smoke alarm is not within each sleeping room. The porch/entrance does not have a smoke alarm. Futon placed in this area which can be used for sleeping. Both first floor bedrooms do not have a smoke alarm.

      Correction: Provide a smoke alarm within each sleeping room.

      Code ATCP 72.18(11)(b)3.

    • Not serious Priority Foundation

      Handrail on stairs > 3 risers

      The stairs leading to the basement is not provided with a handrail. Washer & Dryer are in basement. Guests have access to basement.

      Correction: At least one handrail shall be provided for a flight of stairs with more than 3 risers.

      Code ATCP 72.18(2)(a)1.

    • Not serious Priority Foundation

      Bunk beds - 2.5' spacing between beds

      A vertical separation of less than 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed was observed first floor right bedroom.

      Correction: Provide a vertical separation of at least 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed.

      Code ATCP 72.18(3)(d)2.

    • Not serious Priority Foundation

      Bunk beds - 2.5' spacing between top bed and ceiling

      A free space of less than 2.5 feet was observed above the mattress of the upper bunk bed first floor right bedroom.

      Correction: Provide a free space of at least 2.5 feet above the mattress of the upper bunk bed.

      Code ATCP 72.18(3)(d)3.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

    • Not serious Non-critical

      Common areas maintained in good repair

      The kitchen cabinet is broke and is not maintained in good repair. See attached photo.

      Correction: Maintain all common areas in a good repair.

      Code ATCP 72.19(1)(b)3

  2. Aug 11, 2025 Routine · 2 non-critical
    • Not serious Non-critical

      TOP BUNK-MISSING RAILS

      The bunk bed's top bunk guard rail does not meet the minimum height above the mattress of at least 5-inches.

      Correction: Either increase the top bunk's guard rail height to be at least 5-inches above the mattress or swap out the current mattress in top bunk with a thinner one as soon as possible. Install railings that are in compliance with 16 CFR 1513.

      Code Wisconsin Statute 97.02

    • Not serious Non-critical

      UTENSIL SANITIZATION - CLEANING PROCEDURES

      Bleach is not being provided to sanitize dishes.

      Correction: Provide bleach in facility for guest use as listed in cleaning dishes/utensils procedures as soon as possible. All multi-use utensils must be washed, rinsed and sanitized using approved methods, equipment and chemicals. Provide approved 3 compartment sink or approved commercial dish machine for this purpose. Test sanitizer strength in manual/mechanical methods. Provide means of testing hot water s

      Code [A] ATCP 72.11 (3)(a)

  3. Aug 13, 2024 Routine · 1 non-critical
    • Not serious Non-critical

      PERMIT NOT DISPLAYED IN PUBLIC VIEW

      Current permit is not displayed conspicuously to the public.

      Correction: Post the current permit in a conspicuous location to the public.

      Code ATCP 72.04 (7)

  4. Jul 6, 2023 Routine · No items found

    No violations cited.

Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.