Van Vliet Lakehouse
12070 BAER RD, Presque Isle, WI 54557 · Vilas County
Establishment
- Type
- Lodging (Tourist Rooming House - 1 TRH)
- Inspected by
- Vilas County Public Health
- License / ID
- GSKK-D8DRC8
- Status
- Permitted
- Phone
- (608) 347-8025
- Official record
- Vilas County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 10 | 6 |
| 2025 | 1 | 1 | 0 |
| 2024 | 2 | 1 | 0 |
Inspections
-
Sep 16, 2026 Follow Up · 5 non-critical, 4 repeat
-
Serious
Critical
Repeat
Carbon monoxide alarm installation - FBA within IKU or sleeping room
A carbon monoxide alarm is not provided, outside of each separate sleeping area. The upstairs sleeping rooms do not have a carbon monoxide alarm outside of the sleeping rooms.
Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.
Code ATCP 72.18(12)(b)
-
Serious
Critical
Second floor sleeping room - 2 exits provided
The second floor used for sleeping was not provided with at least 2 separate exits.
Correction: Provide at least 2 separate exits from the second floor used for sleeping or discontinue sleeping from that floor.
Code ATCP 72.18(4)(c)
-
Serious
Critical
Repeat
Windows used for exiting - 20 inches x 24 inches
The second floor windows used for exiting has a window opening of 13 inches wide.
Correction: Provide a window opening at least 20 inches by 24 inches irrespective of the height or width, or provide a different exit, or discontinue sleeping from that floor.
Code ATCP 72.18(4)(g)2.
-
Not serious
Priority Foundation
Repeat
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Not serious
Priority Foundation
Repeat
Guest-provided sanitization - sanitizer provided
A chemical sanitizer for utensils is not provided.
Correction: The chemical sanitizer must be available or made available upon request.
Code ATCP 72.20(6)(e)4.
-
Serious
Critical
Repeat
-
Sep 9, 2026 Routine · 5 non-critical
-
Serious
Critical
Carbon monoxide alarm installation - FBA within IKU or sleeping room
A carbon monoxide alarm is not provided, outside of each separate sleeping area. The upstairs sleeping rooms do not have a carbon monoxide alarm outside of the sleeping rooms.
Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.
Code ATCP 72.18(12)(b)
-
Serious
Critical
First floor sleeping room - 2 exits provided
The first floor used for sleeping was not provided with at least 2 separate exits.
Correction: Provide at least 2 separate exits from the first floor used for sleeping or discontinue sleeping from that floor.
Code ATCP 72.18(4)(b)
-
Serious
Critical
Windows used for exiting - 20 inches x 24 inches
The second floor windows used for exiting has a window opening of 13 inches wide.
Correction: Provide a window opening at least 20 inches by 24 inches irrespective of the height or width, or provide a different exit, or discontinue sleeping from that floor.
Code ATCP 72.18(4)(g)2.
-
Not serious
Priority Foundation
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Not serious
Priority Foundation
Guest-provided sanitization - sanitizer provided
A chemical sanitizer for utensils is not provided.
Correction: The chemical sanitizer must be available or made available upon request.
Code ATCP 72.20(6)(e)4.
-
Serious
Critical
-
Sep 9, 2025 Routine · 1 non-critical
-
Not serious
Non-critical
PERMIT NOT DISPLAYED IN PUBLIC VIEW
Permit is not displayed conspicuously to the public.
Correction: Post the permit in a conspicuous location to the public.
Code ATCP 72.04 (7)
-
Not serious
Non-critical
-
Dec 3, 2024 Pre-inspection Follow Up · No items found
No violations cited.
-
Aug 22, 2024 Pre-inspection · 1 non-critical
-
Not serious
Non-critical
GENERAL MAINTENANCE
No hand rail or guards on open side of stairs going into the basement.
Correction: Maintained establishment in a manner conducive to the health, comfort and safety of its guests. Handrail and guards shall be constructed to SPS 321.04 (3) Standards and you will have 90 Days to correct violation. Permit will be held until violation is corrected.
Code [C] ATCP 72.15 (1)
-
Not serious
Non-critical
Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.