RecordWell Data

Knott Too Small Escape

1925 PINEWOOD DR, Eagle River, WI 54521 · Vilas County

11cited violations
5serious tier
1inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Vilas County Public Health
License / ID
BHAA-DXWJGH
Status
Pending
Phone
(262) 237-7427 ext. Nate
Official record
Vilas County Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20261115

Inspections

  1. Sep 9, 2026 Pre-inspection · 11 non-critical
    • Serious Critical

      POWTS access covers

      The POWTS access cover was observed unlocked.

      Correction: Locked or secure the POWTS access cover to prevent general access by the public.

      Code ATCP 72.17(3)(b)

    • Serious Critical

      Carbon monoxide alarm installation - FBA within IKU or sleeping room

      A carbon monoxide alarm is not provided outside of each separate sleeping area.

      Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.

      Code ATCP 72.18(12)(b)

    • Serious Critical

      Basement or ground floor sleeping room - 2 exits provided

      The basement or ground floor used for sleeping was not provided with at least 2 separate exits.

      Correction: Provide at least 2 separate exits from the basement or ground floor used for sleeping or discontinue sleeping from that floor.

      Code ATCP 72.18(4)(ar)

    • Serious Critical

      Second floor sleeping room - 2 exits provided

      The second floor used for sleeping was not provided with at least 2 separate exits.

      Correction: Provide at least 2 separate exits from the second floor used for sleeping or discontinue sleeping from that floor.

      Code ATCP 72.18(4)(c)

    • Serious Critical

      Windows used for exiting - 20 inches x 24 inches

      Sleeping room windows on the second floor and in the basement, used for exiting, do not meet egress requirements.

      Correction: Provide a window opening at least 20 inches by 24 inches irrespective of the height or width, or provide a different exit, or discontinue sleeping from that floor.

      Code ATCP 72.18(4)(g)2.

    • Not serious Priority Foundation

      Smoke alarm installed in each sleeping room

      A smoke alarm is not within each sleeping room. The basement bedroom (with bathroom) does not have a smoke alarm.

      Correction: Provide a smoke alarm within each sleeping room.

      Code ATCP 72.18(11)(b)3.

    • Not serious Priority Foundation

      Guards provided on stairs > 3 risers

      Guards are not provided on all open sides of the deck stairs (grill side).

      Correction: Guards shall be provided on all open sides of stairs consisting of more than 3 risers.

      Code ATCP 72.18(2)(b)1.

    • Not serious Priority Foundation

      Guard height >= 36" - elevated surfaces

      The guard height is less than 36 inches on the deck corner (grill side) as measured vertically above the adjacent walking surface.

      Correction: Modify the guard height to be equal to or greater than 36 inches on the deck in areas that are elevated >30" as measured vertically above the adjacent walking surface.

      Code ATCP 72.18(2)(b)6.a.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

    • Not serious Non-critical

      Pest control - openable windows screened

      The window(s) in the basement is not screened.

      Correction: All openable windows within in individually keyed units need to have a screen.

      Code ATCP 72.19(2)(a)3.b.

    • Not serious Non-critical

      Nonabsorbent mattress cover or mattress surface

      Mattress are not provided with a nonabsorbent mattress protector that covers the entire sleeping surface.

      Correction: Provide a nonabsorbent mattress protector that covers the entire sleeping surface or have an easily cleanable nonabsorbent mattress surface.

      Code ATCP 72.20(8)(d)

Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.