Shields Road Condo #8
1660 SHIELDS RD, Saint Germain, WI 54558 · Vilas County
Establishment
- Type
- Lodging (Tourist Rooming House - 1 TRH)
- Inspected by
- Vilas County Public Health
- License / ID
- SZEN-D53PEQ
- Status
- Permitted
- Phone
- (262) 344-6340
- Official record
- Vilas County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 3 | 0 |
| 2025 | 1 | 0 | 0 |
| 2024 | 2 | 1 | 1 |
Inspections
-
Jun 23, 2026 Routine · 3 non-critical
-
Not serious
Priority Foundation
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Not serious
Non-critical
License posted in public view
A current license is not posted on the premises in a place visible to the public.
Correction: Post a current license in the premises in a place visible to the public.
Code ATCP 72.07(7)
-
Not serious
Non-critical
Food-contact utensil surfaces - nonabsorbent
The wooden utensil or dishware surface is absorbent. Wooden spoon observed in kitchen.
Correction: Discontinue use of the food-contact utensil or dishware.
Code ATCP 72.20(5)(f)
-
Not serious
Priority Foundation
-
Jun 23, 2026 Follow Up · No items found
No violations cited.
-
Jun 7, 2025 Routine · No items found
No violations cited.
-
May 13, 2024 Re-inspection · No items found
No violations cited.
-
May 9, 2024 Pre-inspection · 1 critical
-
Serious
Critical
GENERAL MAINTENANCE
Deck does not meet code standards. Guardrail is present only on one side of the flight of stairs and does not have any guards (open space between rails measures 33 inches. Horizontal guards exceed spacing requirements measuring 5.75-6 inches. Guards and guardrails absent behind grill on deck.
Correction: Maintained establishment in a manner conducive to the health, comfort and safety of its guests. Update deck to meet SPS 321.04 code standards.Deck must be reinspected and brought up to code standard within 90 days (by August 7, 2024). Contact Sarah at 715-479-3758 or zeltens@uwosh.edu to schedule reinspection upon completion. If extension is needed to complete project contact Sarah.
Code [C] ATCP 72.15 (1)
-
Serious
Critical
Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.