Yeagermeister, LLC
5462 ABE LA FAVE TRL, Manitowish Waters, WI 54545 · Vilas County
Establishment
- Type
- Lodging (Tourist Rooming House - 1 TRH)
- Inspected by
- Vilas County Public Health
- License / ID
- TAYL-AYKLT5
- Status
- Permitted
- Phone
- (608) 852-4461
- Official record
- Vilas County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 6 | 2 |
| 2025 | 1 | 0 | 0 |
| 2024 | 1 | 0 | 0 |
| 2023 | 1 | 0 | 0 |
Inspections
-
Oct 5, 2026 Follow Up · No items found
No violations cited.
-
Aug 10, 2026 Routine · 6 non-critical
-
Serious
Critical
Smoke alarm maintained - working order; expiration
The smoke alarms in both bedrooms are expired. The smoke alarm in the left bedroom is maintained in working order,replaced in accordance with the manufacturer’s date of expiration.
Correction: Repair or replace the smoke alarm within 5 calendar days.
Code ATCP 72.18(11)(e)
-
Serious
Critical
Carbon monoxide alarm maintained - working order; expiration
The carbon monoxide alarm in the living room is not is expired. Rreplaced in accordance with the manufacturer’s date of expiration.
Correction: Repair or replace the carbon monoxide alarm within 5 calendar days.
Code ATCP 72.18(12)(h)
-
Not serious
Priority Foundation
Handrail on stairs > 3 risers
The staircase leading to the basement is not provided with a handrail.
Correction: At least one handrail shall be provided for a flight of stairs with more than 3 risers.
Code ATCP 72.18(2)(a)1.
-
Not serious
Priority Foundation
Guards provided > 30" fall
The landing leading to the basement stairs is not provided with guards on all open sides that are elevated more than 30 inches above the floor or grade.
Correction: Provide guards on all open sides of the landing area leading to the basement that are elevated more than 30 inches above the floor or grade.
Code ATCP 72.18(2)(b)2.
-
Not serious
Priority Foundation
Guard spacing <= 6"
The space between guards, and the space formed between the bottom guard on the landing leading to the basement is more than 6 inches.
Correction: Modify the space between guards, and the space formed between the bottom guard and the landing to be equal to or less than 6 inches.
Code ATCP 72.18(2)(b)3.
-
Not serious
Priority Foundation
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Serious
Critical
-
Jun 2, 2025 Routine · No items found
No violations cited.
-
Jun 19, 2024 Routine · No items found
No violations cited.
-
Jun 2, 2023 Routine · No items found
No violations cited.
Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.