Vermiglio's Heritage
6325 VERMIGLIO'S HERITAGE LN, Manitowish Waters, WI 54545 · Vilas County
Establishment
- Type
- Lodging (Tourist Rooming House - 2 - 4 TRH)
- Inspected by
- Vilas County Public Health
- License / ID
- BHEP-7VFLSF
- Status
- Permitted
- Phone
- (847) 212-7999
- Official record
- Vilas County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 8 | 4 |
| 2025 | 1 | 0 | 0 |
| 2023 | 1 | 0 | 0 |
Inspections
-
Jul 27, 2026 Follow Up · 4 non-critical, 4 repeat
-
Serious
Critical
Repeat
Carbon monoxide alarm installation - FBA within IKU or sleeping room
A carbon monoxide alarm is not provided outside of each separate sleeping area within 21 feet of any door to a sleeping room. The CO detector in the living room needs to be moved closer to the bedrooms.
Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.
Code ATCP 72.18(12)(b)
-
Serious
Critical
Repeat
First floor sleeping room - 2 exits provided
The first floor used for sleeping was not provided with at least 2 separate exits.
Correction: Provide at least 2 separate exits from the first floor used for sleeping or discontinue sleeping from that floor.
Code ATCP 72.18(4)(b)
-
Not serious
Priority Foundation
Repeat
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Not serious
Non-critical
Repeat
Ceiling height >= 7'
At least 50 percent of each sleeping room’s floor area does not have a ceiling height of at least 7 feet.
Correction: Remove beds or apply for a variance.
Code ATCP 72.18(3)(a)
-
Serious
Critical
Repeat
-
Jun 30, 2026 Routine · 4 non-critical
-
Serious
Critical
Carbon monoxide alarm installation - FBA within IKU or sleeping room
A carbon monoxide alarm is not provided outside of each separate sleeping area within 21 feet of any door to a sleeping room. The CO detector in the living room needs to be moved closer to the bedrooms.
Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.
Code ATCP 72.18(12)(b)
-
Serious
Critical
First floor sleeping room - 2 exits provided
The first floor used for sleeping was not provided with at least 2 separate exits.
Correction: Provide at least 2 separate exits from the first floor used for sleeping or discontinue sleeping from that floor.
Code ATCP 72.18(4)(b)
-
Not serious
Priority Foundation
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Not serious
Non-critical
Ceiling height >= 7'
At least 50 percent of each sleeping room’s floor area does not have a ceiling height of at least 7 feet.
Correction: Remove beds or apply for a variance.
Code ATCP 72.18(3)(a)
-
Serious
Critical
-
Jun 30, 2025 Routine · No items found
No violations cited.
-
Jun 24, 2023 Routine · No items found
No violations cited.
Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.