Acorn Lodge Swimming Pool
10370 MAIN ST, Boulder Junction, WI 54512 · Vilas County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Vilas County Public Health
- License / ID
- ASPR-9VJHRH
- Status
- Permitted
- Phone
- (715) 385-2150
- Official record
- Vilas County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 26 | 8 |
| 2024 | 1 | 1 | 1 |
| 2023 | 1 | 2 | 2 |
Inspections
-
Sep 29, 2026 Re-inspection · 1 critical, 8 non-critical, 9 repeat
-
Not serious
Non-critical
Repeat
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer or screen not available
Correction: Provide a spare strainer or screen
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
Repeat
SAFETY DATA SHEET
A safety data sheet was not available in the facility.
Correction: Maintain a safety data sheet for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool. Contents. A biohazard kit shall contain all the following: 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24Y x 24Y. 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises. VGBA drain cover was installed in 2017 with an expiration date of 2022.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
Repeat
FILES RETAINED 2 YEARS-DAILY INSPECTIONS AND OPERATIONAL TESTS
Daily inspection and operational tests records not maintained on premises for 2 years.
Correction: Maintain on premises for 2 years reports of daily inspections and operational tests.
Code ATCP 76.32(3)(b)4. - DAILY INSPECTION AND OPERATIONAL TESTS
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. No VGBA drain cover log available. Intallation documents mark 2017 VGBA installation date with VGBA expiration 2022.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
Repeat
HAZARDOUS CONDITION
There is a hazardous condition at the pool. No updated VGBA documents provided. Current VGBA drain was installed in 2017 with an expiration date of 2022.
Correction: Correct the hazardous condition and contact DSPS and certified pool operator to inspect VGBA drain for pool and whirpool.
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Not serious
Non-critical
Repeat
-
Aug 31, 2026 Routine · 7 critical, 10 non-critical
-
Not serious
Non-critical
SPARE STRAINER BASKET OR SCREEN AVAILABLE
Spare strainer or screen not available
Correction: Provide a spare strainer or screen
Code ATCP 76.11(2)(d) 2. - SPARE STRAINER OR SCREEN
-
Not serious
Non-critical
SAFETY DATA SHEET
A safety data sheet was not available in the facility.
Correction: Maintain a safety data sheet for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
FLOW-THROUGH FEEDERS-USE
The facility does not provide a chemcial feeder device.
Correction: Ensure that each pool in use is automatically and continuously disinfected by means of disinfectant or sanitizer and feeding equipment that is in compliance with this section and s. ATCP 76.13.
Code ATCP 76.14 (4)(b) - FLOW-THROUGH CHEMICAL FEEDER
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is less than 10 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
BIOHAZARD KIT-AVAILABLE
A biohazard kit is not available.
Correction: Provide a biohazard kit for the pool. Contents. A biohazard kit shall contain all the following: 1. Scoop and spatula. 2. Sanitizing hand wipes. 3. Sanitizing surface wipes. 4. Neoprene gloves. 5. Paper toweling. 6. Biohazard disposal bag at least 24Y x 24Y. 7. Twist tie or other effective means to close the bag. 8. Biohazard sorbent. 9. Storage case.
Code ATCP 76.27(2)(a) - BIOHAZ KIT AVAILABLE
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises. VGBA drain cover was installed in 2017 with an expiration date of 2022.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
FILES RETAINED 2 YEARS-DAILY INSPECTIONS AND OPERATIONAL TESTS
Daily inspection and operational tests records not maintained on premises for 2 years.
Correction: Maintain on premises for 2 years reports of daily inspections and operational tests.
Code ATCP 76.32(3)(b)4. - DAILY INSPECTION AND OPERATIONAL TESTS
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. No VGBA drain cover log available. Intallation documents mark 2017 VGBA installation date with VGBA expiration 2022.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
RECIRCULATION SYSTEM CONTINUOUS OPERATION
The pool recirculation system is not operational or not continuously operated. The facility does not provide any automatic chemical feeder equipment to dispense disinfectant and sanitizer chemicals into the pool system.
Correction: The pool must be closed immediately until the recirculation system is in place and in continuous operation.
Code ATCP 76.11(1) - RECIRCULATION SYSTEM PRESENT, CONTINUOUSLY O
-
Serious
Critical
INTERLOCK-PRESENT (Electrical or Flow)
Recirculation system not equipped with either electrical or flow interlock.
Correction: Install proper chemical feed interlocks.
Code ATCP 76.13(1)(c) - INTERLOCK OF EITHER TYPE PRESENT
-
Serious
Critical
AUTOMATIC AND CONTINUOUS DISINFECTION
Pool not automatically and continuously disinfected by means of disinfectant or sanitizer and feeding equipment. The pool recirculation systems shall be equipped with a chemical feed interlock
Correction: Ensure that each pool in use is automatically and continuously disinfected by means of disinfectant or sanitizer and feeding equipment that is in compliance with this section and s. ATCP 76.13.
Code ATCP 76.14 (1) - AUTOMATIC DISINFECTION
-
Serious
Critical
TELEPHONE ACCESSIBLE
A telephone or other approved communication technology capable of connecting to emergency services is not working or not present.
Correction: Provide a working telephone or other technology capable of connecting with emergency services.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Serious
Critical
CLOSING CRITERIA-NON-OPERATIONAL RECIRD PUMP
The Responsible Supervisor or operator has not closed the pool when there is a nonoperational circulation pump, filter, or disinfectant or sanitizer feeder. The facility does not provide an automatic recirculation interlock chemical feeder.
Correction: Close the pool in the event of a nonoperational circulation pump, filter, or disinfectant or sanitizer feeder.
Code ATCP 76.30 (1)(d) - NON-OPERATIONAL RECIRC PUMP
-
Serious
Critical
CLOSING CRITERIA-NO FUNCTIONAL EMERGENCY PHONE
The Responsible Supervisor or operator has not closed the pool due to a nonfunctional emergency phone.
Correction: Close the pool in the event of a nonfunctional emergency phone.
Code ATCP 76.30 (1)(g) - FUNCTIONAL EMERGENCY PHONE
-
Serious
Critical
HAZARDOUS CONDITION
There is a hazardous condition at the pool. No updated VGBA documents provided. Current VGBA drain was installed in 2017 with an expiration date of 2022.
Correction: Correct the hazardous condition and contact DSPS and certified pool operator to inspect VGBA drain for pool and whirpool.
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Not serious
Non-critical
-
Oct 25, 2024 Routine · 1 critical
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 0.37 (Liquid Chlorine).
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. Proof of correction was not submitted to the department Friday afternoon. Re-inspection is required.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
-
Oct 13, 2023 Routine · 2 critical
-
Serious
Critical
TELEPHONE ACCESSIBLE
A telephone or other approved communication technology capable of connecting to emergency services is not present.
Correction: Provide a working telephone or other technology capable of connecting with emergency services. Correct by next routine inspection.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Serious
Critical
GATES AND DOORS-LATCHING
The gate or door does not latch. This is no latching mechanism on the door
Correction: Provide a latching door. Correct by next routine inspection.
Code ATCP 76.34(4)(a)(1m)(b)- LATCHING
-
Serious
Critical