RecordWell Data

Corsair Development LLC

7670 HUG LN, Saint Germain, WI 54558 · Vilas County

11cited violations
4serious tier
4inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Vilas County Public Health
License / ID
SZEN-D5YKM3
Status
Permitted
Phone
(847) 327-5481
Official record
Vilas County Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026183
2025100
2024231

Inspections

  1. Aug 31, 2026 Routine · 8 non-critical
    • Serious Critical

      Smoke alarms provided

      Smoke alarms are not adequately provided within each individually keyed unit.

      Correction: Provide smoke alarms within each individually keyed unit at the locations specified in rule.

      Code ATCP 72.18(11)(a)

    • Serious Critical

      Carbon monoxide alarm installation - FBA within IKU or sleeping room

      A carbon monoxide alarm is not provided outside of each separate sleeping area or in the sleeping room with the fuel burning appliance. No carbon monoxide alarm was found in or outside the basement sleeping areas.

      Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.

      Code ATCP 72.18(12)(b)

    • Serious Critical

      Basement or ground floor sleeping room - 2 exits provided

      The basement bedrooms used for sleeping are not provided with at least 2 separate exits. Basement with one interior stairway did not also provide acceptable egress windows in each sleeping area.

      Correction: Provide acceptable egress windows in each sleeping room or discontinue use of bedrooms that do not have acceptable egress windows.

      Code ATCP 72.18(4)(ar)

    • Not serious Priority Foundation

      Smoke alarm installed in each sleeping room

      A smoke alarm is not within each sleeping room. The basement bedroom on the right does not have a smoke alarm.

      Correction: Provide a smoke alarm within each sleeping room.

      Code ATCP 72.18(11)(b)3.

    • Not serious Priority Foundation

      Handrail on stairs > 3 risers

      The basement stairwell is not provided with a handrail for all stairs. Handrail is provided for bottom half of stairs but lacking for top half.

      Correction: Add a section of handrail so that all stairs have a handrail.

      Code ATCP 72.18(2)(a)1.

    • Not serious Priority Foundation

      Guards provided on stairs > 3 risers

      Guards are not provided on all open sides of stairs to basement. Guards do not extend all the way down the stairway.

      Correction: Guards shall be provided on all open sides of stairs consisting of more than 3 risers.

      Code ATCP 72.18(2)(b)1.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

    • Not serious Non-critical

      License posted in public view

      A current license is not posted on the premises in a place visible to the public.

      Correction: Post a current license in the premises in a place visible to the public.

      Code ATCP 72.07(7)

  2. Aug 11, 2025 Routine · No items found

    No violations cited.

  3. Jun 21, 2024 Follow Up · No items found

    No violations cited.

  4. Jun 10, 2024 Pre-inspection · 1 critical, 2 non-critical
    • Not serious Non-critical Corrected on site

      UTENSIL SANITIZATION - CLEANING PROCEDURES

      Multi-use food contact surfaces, such as glassware and utensils, are not being washed, rinsed and sanitized for different guests.

      Correction: All multi-use utensils must be washed, rinsed and sanitized using approved methods, equipment and chemicals. Provided utensil sanitation poster today to post in facility. No utensils for food contact may be washed in a guestroom lavatory.

      Code [A] ATCP 72.11 (3)(a)

    • Not serious Non-critical

      GENERAL MAINTENANCE

      Nonperishable food items are present in the refrigerator and kitchen cabinets.

      Correction: Maintained establishment in a manner conducive to the health, comfort and safety of its guests. Remove potentially hazardous food items from facility between guests. Correct prior to next routine inspection.

      Code [C] ATCP 72.15 (1)

    • Serious Critical

      PRIVATE WELL-WATER UNSAFE; POTABLE WATER PROVISIONS

      The well water from the well servicing this property has been determined by laboratory analysis to be unsafe per DNR 809 standards. Sample tested positive for Coliform and negative for E. coli bacteria.

      Correction: Provide safe potable water from a tested and approved source on a temporary basis until the well is tested safe or a new well is drilled and the water is determined safe. Immediately discontinue use of the well's water supply for drinking, cooking and ice making purposes. Bathing is OK. Provide bottled water and ice supply from an approved source until a safe on-premise water supply is available.

      Code [E] ATCP 72.10 (3)

Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.