RecordWell Data

Eagles Nest Retreat

1015 PHILLIPS PL, Saint Germain, WI 54558 · Vilas County

13cited violations
3serious tier
3inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Vilas County Public Health
License / ID
TAYL-C4JNNA
Status
Permitted
Phone
(715) 360-5956
Official record
Vilas County Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20261123
2025110
2024100

Inspections

  1. Mar 23, 2026 Routine · 11 non-critical
    • Serious Critical

      Smoke alarm maintained - working order; expiration

      The smoke alarm on main floor (1st room on the left) is not maintained in working order.

      Correction: Repair or replace the smoke alarm within 5 calendar days.

      Code ATCP 72.18(11)(e)

    • Serious Critical

      Smoke alarm maintained - working order; expiration

      The smoke alarms at the top of stairs and the 2 alarms in the main floor hallway are not in accordance with the manufacturer’s date of expiration.

      Correction: Repair or replace the smoke alarms within 5 calendar days.

      Code ATCP 72.18(11)(e)

    • Serious Critical

      Carbon monoxide alarms provided

      A carbon monoxide alarm is not provided anywhere in the lodging facility that also contains a fuel-burning appliance.

      Correction: Provide carbon monoxide alarms at the locations specified in rule. This facility requires 1 CO alarm installed in the hallway upstairs and 2 CO alarms in the basement to meet distance requirement.

      Code ATCP 72.18(12)(a)

    • Not serious Priority Foundation

      Smoke alarm installed outside each separate sleeping area

      A smoke alarm is not provided outside of each separate sleeping area, within 21 feet of any door to a sleeping room. The basement hallway does not have a smoke alarm.

      Correction: Provide a smoke alarm outside of each separate sleeping area, within 21 feet of any door to a sleeping room. The basement will require 2 smoke alarms to meet distance requirement.

      Code ATCP 72.18(11)(b)2.

    • Not serious Priority Foundation

      Carbon monoxide alarm installation - FBA outside IKU

      A carbon monoxide alarm is not provided outside of each separate sleeping area within the individually keyed units.

      Correction: Provide carbon monoxide alarm outside of each separate sleeping area within the individually keyed units.

      Code ATCP 72.18(12)(c)

    • Not serious Priority Foundation

      Windows used for exiting - platform for windows > 46 inches above floor

      All the sleeping room's in the basement with a window used for exiting does not have a permanent platform or fixture installed.

      Correction: Provide a permanent platform or fixture that is at least 20 inches wide and 9 inches deep is located no more than 46 inches directly below the clear opening, or provide a different exit, or discontinue sleeping rooms on that floor. A bed is not a permanent platform or fixture.

      Code ATCP 72.18(4)(g)5.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

    • Not serious Priority Foundation

      TCS foods, opened non-TCS foods, ice - removal at guest turnover

      Opened non-TCS food item (ice) was not discarded between guest stays.

      Correction: Discard all TCS foods and opened non-TCS food items including ice at guest turnover.

      Code ATCP 72.21(3)

    • Not serious Non-critical

      License posted in public view

      A current license is not posted on the premises in a place visible to the public.

      Correction: Post a current license in the premises in a place visible to the public.

      Code ATCP 72.07(7)

    • Not serious Non-critical

      Ceiling height >= 7'

      At least 50 percent of the basement sleeping room’s (end of hallway) floor area does not have a ceiling height of at least 7 feet.

      Correction: Remove bed or apply for a variance through our department and the DATCP.

      Code ATCP 72.18(3)(a)

    • Not serious Non-critical

      Equipment and furnishings - maintained clean

      The refrigerator located in the garage appears to have not been cleaned for an extended period of time.

      Correction: All furnishings and equipment and shall be kept clean.

      Code ATCP 72.20(4)(a)

    • Not serious Non-critical

      Food-contact utensil surfaces - nonabsorbent

      The kitchen has wooden utensils. Wooden utensils are an absorbent food-contact utensil/dishware.

      Correction: Discontinue use of the food-contact utensil or dishware.

      Code ATCP 72.20(5)(f)

  2. Jun 25, 2025 Routine · 1 non-critical
    • Not serious Non-critical

      UTENSIL SANITIZATION - CLEANING PROCEDURES

      Multi-use food contact surfaces, such as [items] are not being washed, rinsed and sanitized for different guests.Utensils/dishes cleaning procedure note not found in the facility. The inspector left a copy of note on the refrigerator which must be displayed in public view for guests.

      Correction: All multi-use utensils must be washed, rinsed and sanitized using approved methods, equipment and chemicals. Provide approved 3 compartment sink or approved commercial dish machine for this purpose or provide bleach for guests to sanitize dishes. No utensils for food contact may be washed in a guestroom lavatory.

      Code [A] ATCP 72.11 (3)(a)

  3. Jun 11, 2024 Routine · No items found

    No violations cited.

Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.