Birchwood Retreat
1190 WILKE TRL, Saint Germain, WI 54558 · Vilas County
Establishment
- Type
- Lodging (Tourist Rooming House - 1 TRH)
- Inspected by
- Vilas County Public Health
- License / ID
- THAS-9YLM8R
- Status
- Permitted
- Phone
- (715) 891-4307
- Official record
- Vilas County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 4 | 1 |
| 2025 | 1 | 1 | 1 |
| 2024 | 1 | 0 | 0 |
| 2023 | 1 | 1 | 0 |
Inspections
-
Aug 10, 2026 Routine · 4 non-critical
-
Serious
Critical
Slip-resistant flooring in shower and bathtubs
The shower or bathtub is not provided with slip-resistant flooring or materials.
Correction: Slip-resistant flooring or materials shall be provided in all shower and bathtub basins.
Code ATCP 72.17(5)(f)
-
Not serious
Priority Foundation
Guards provided on stairs > 3 risers
Guards are not provided on all open sides of stairs to deck and stairs to side door.
Correction: Guards with spacings of less than or equal to 6 inches shall be provided on all open sides of stairs consisting of more than 3 risers.
Code ATCP 72.18(2)(b)1.
-
Not serious
Priority Foundation
Guard spacing <= 6"
The space between guards, and the space formed between the bottom guard and the deck surface, is more than 6 inches. This is a repeat violation.
Correction: Modify the space between guards, and the space formed between the bottom guard and the deck, to be equal to or less than 6 inches.
Code ATCP 72.18(2)(b)3.
-
Not serious
Priority Foundation
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Serious
Critical
-
Jun 8, 2025 Routine · 1 critical
-
Serious
Critical
GENERAL MAINTENANCE
Deck gaurdrail greater than six inches apart and/or handrail not 36 inches. Bleach not provided for sanitizaiton of kitchenwear
Correction: Maintained establishment in a manner conducive to the health, comfort and safety of its guests. Handrail provided. A flight of stairs with more than 3 risers shall be provided with at least one handrail. Guards shall be provided on all open sides of stairs consisting of more than 3 risers. All elevated surfaces in interior and exterior structures shall be provided with guards on all open sides tha
Code [C] ATCP 72.15 (1)
-
Serious
Critical
-
Jun 17, 2024 Routine · No items found
No violations cited.
-
Jun 12, 2023 Routine · 1 non-critical
-
Not serious
Non-critical
PREMISE - MAINTAINED
Premise is not maintained clean, free from refuse, or other hazards: cable present across yard.
Correction: Maintain premise in a clean condition, free from refuse and hazards. Please have cable buried by next routine inspection.
Code [A] ATCP 72.15 (4)
-
Not serious
Non-critical
Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.