Zauggs Resort
1962 MILITARY, Eagle River, WI 54521 · Vilas County
Establishment
- Type
- Lodging (Tourist Rooming House - 1 TRH)
- Inspected by
- Vilas County Public Health
- License / ID
- HSAT-7QWBWW
- Status
- Permitted
- Phone
- (715) 479-3388
- Official record
- Vilas County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 8 | 3 |
| 2025 | 1 | 1 | 0 |
| 2024 | 1 | 0 | 0 |
Inspections
-
Jun 11, 2026 Routine · 8 non-critical
-
Serious
Critical
Smoke alarms provided
Smoke alarm is not provided at the top of the basement stairway.
Correction: Provide smoke alarms within each individually keyed unit at the locations specified in rule.
Code ATCP 72.18(11)(a)
-
Serious
Critical
Smoke alarm maintained - working order; expiration
All Firex model G-18 hardwired smoke alarms with 5-digit code 96226 were manufactured on Febuary 26, 1996. Smoke alarms are 30 years old.
Correction: Replace the smoke alarm within 5 calendar days.
Code ATCP 72.18(11)(e)
-
Serious
Critical
Carbon monoxide alarm installation - FBA within IKU or sleeping room
A carbon monoxide alarm is not provided outside of each separate sleeping area, lower level bedrooms, main level bedrooms & upper hallway bedrooms.
Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.
Code ATCP 72.18(12)(b)
-
Not serious
Priority Foundation
Smoke alarm installed outside each separate sleeping area
A smoke alarm is not provided outside of each separate sleeping area, within 21 feet of any door to a sleeping room. The main level bedrooms and the upstairs hallway bedrooms do not have a smoke alarm.
Correction: Provide a smoke alarm outside of each separate sleeping area, within 21 feet of any door to a sleeping room.
Code ATCP 72.18(11)(b)2.
-
Not serious
Priority Foundation
Bed placement max ceiling height
The bed placement in the upstairs bedroom end of hall does not provide the occupant with maximum ceiling height clearance for emergency egress.
Correction: Rearrange bed to allow maximum ceiling height clearance for emergency egress.
Code ATCP 72.18(3)(c)
-
Not serious
Priority Foundation
Bunk beds - 2.5' spacing between beds
A vertical separation of less than 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed was observed in the basement bedroom.
Correction: Provide a vertical separation of at least 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed in the basement bedroom..
Code ATCP 72.18(3)(d)2.
-
Not serious
Priority Foundation
Bunk beds - guards 5" above mattress
The top of the guard was less than 5 inches above the top of the mattress of the upper bunk bed agaisnt wall furthest from door in the lower level bedroom.
Correction: Reconstruct the top guard or install a thinner mattress to provide at least 5 inches above the top of the mattress.
Code ATCP 72.18(3)(d)4.a.
-
Not serious
Priority Foundation
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not posted in materials provided to guests.
Correction: Place building evacuation diagram in the material provided to guests.
Code ATCP 72.18(6)(b)1.
-
Serious
Critical
-
May 5, 2025 Routine · 1 non-critical
-
Not serious
Non-critical
GENERAL MAINTENANCE
No Handrail or guards provided on open side of basement steps.
Correction: Maintained establishment in a manner conducive to the health, comfort and safety of its guests. Install guards and handrail on the open side of the staircase to prevent fall injury and meet code standard within 90 days (Aug. 4th, 2025). Send proof of corrections to Bobbie Halada at 715-891-0042 or email to haladab@uwosh.edu or contact Graydon at 715-479-3786 or skokg@uwosh.edu.
Code [C] ATCP 72.15 (1)
-
Not serious
Non-critical
-
May 30, 2024 Routine · No items found
No violations cited.
Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.