  1. Apr 17, 2026 Routine · 5 non-critical
    • Not serious Priority Foundation

      Smoke alarm installed in each sleeping room

      A smoke alarm is not within each sleeping room. .

      Correction: Provide a smoke alarm within each sleeping room.

      Code ATCP 72.18(11)(b)3.

    • Not serious Priority Foundation

      Bed spacing >= 2' egress aisle

      Beds are not arranged to provide an aisle at least 2 feet in width from one side of each bed to create a clear path for emergency egress.

      Correction: Rearrange or remove bed(s) to provide an aisle at least 2 feet in width from one side of each bed to create a clear path for emergency egress.

      Code ATCP 72.18(3)(b)1.

    • Not serious Priority Foundation

      Bunk beds - 2.5' spacing between beds

      A vertical separation of less than 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed was observed.

      Correction: Provide a vertical separation of at least 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed.

      Code ATCP 72.18(3)(d)2.

    • Not serious Priority Foundation

      Bunk beds - 2.5' spacing between top bed and ceiling

      A free space of less than 2.5 feet was observed above the mattress of the upper bunk bed.

      Correction: Provide a free space of at least 2.5 feet above the mattress of the upper bunk bed.

      Code ATCP 72.18(3)(d)3.

    • Not serious Priority Foundation

      Bunk beds - 3.5" spacing between mattress and bottom guard

      The bottom of the guard is more than 3.5 inches above the top of the upper bunk bed frame.

      Correction: Reconstruct the top guard to provide no more than 3.5 inches between the guard and upper bunk bed frame.

      Code ATCP 72.18(3)(d)4.b.

  2. Jun 9, 2025 Follow Up · 2 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      DESIGN-CONSTRUCTION, MATERIALS, EASILY CLEANABLE, DURABLE

      Bunk beds do not meet code.

      Correction: Provide complying furnishings. Bring bunk beds up to code or remove them.

      Code ATCP 72.11 (1)

    • Not serious Non-critical Repeat

      GENERAL MAINTENANCE

      Outside stairs do not have guardrails or are not up to code.

      Correction: Bring all stairs and elevated surfaces up to code. Maintained establishment in a manner conducive to the health, comfort and safety of its guests.

      Code [C] ATCP 72.15 (1)

  3. Apr 25, 2025 Pre-inspection · 2 non-critical
    • Not serious Non-critical

      DESIGN-CONSTRUCTION, MATERIALS, EASILY CLEANABLE, DURABLE

      Bunk beds do not meet code.

      Correction: Provide complying furnishings. Bring bunk beds up to code or remove them.

      Code ATCP 72.11 (1)

    • Not serious Non-critical

      GENERAL MAINTENANCE

      Outside stairs do not have guardrails or are not up to code.

      Correction: Bring all stairs and elevated surfaces up to code. Maintained establishment in a manner conducive to the health, comfort and safety of its guests.

      Code [C] ATCP 72.15 (1)