RecordWell Data

Adventure House LLC

14039 ADELAIDE DR, Winchester, WI 54557 · Vilas County

10cited violations
2serious tier
4inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Vilas County Public Health
License / ID
GSKK-CXCHS7
Status
Permitted
Phone
(920) 460-6698
Official record
Vilas County Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026192
2025100
2024100
2023110

Inspections

  1. Oct 26, 2026 Routine · 9 non-critical
    • Serious Critical

      Carbon monoxide alarms provided

      A carbon monoxide alarm is not provided anywhere in the lodging facility that also contains a fuel-burning appliance.

      Correction: Provide carbon monoxide alarms at the locations specified in rule.

      Code ATCP 72.18(12)(a)

    • Serious Critical

      Carbon monoxide alarm installation - FBA within IKU or sleeping room

      A carbon monoxide alarm is not provided outside of each separate sleeping area and not within the bunk bed sleeping room with fuel-burning appliance in closet.

      Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom. A CO alarm shall be installed in the loft sleeping area, the hallway on main floor, and within the bunk bed sleeping room.

      Code ATCP 72.18(12)(b)

    • Not serious Priority Foundation

      Smoke alarm installed in each sleeping room

      A smoke alarm is not within each sleeping room. The bunk bed sleeping room does not have a smoke alarm.

      Correction: Provide a smoke alarm within each sleeping room.

      Code ATCP 72.18(11)(b)3.

    • Not serious Priority Foundation

      Guard height >= 36" - elevated surfaces

      The guard height is less than 36 inches on the loft railing as measured vertically above the adjacent walking surface.The measurement taken at the time of the inspection was approximately 34 inches.

      Correction: Modify the guard height to be equal to or greater than 36 inches on loft railing as measured vertically above the adjacent walking surface.

      Code ATCP 72.18(2)(b)6.a.

    • Not serious Priority Foundation

      Bunk beds - 2.5' spacing between beds

      A vertical separation of less than 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed was observed in bunk bed sleeping room.

      Correction: Provide a vertical separation of at least 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed.

      Code ATCP 72.18(3)(d)2.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

    • Not serious Priority Foundation

      TCS foods, opened non-TCS foods, ice - removal at guest turnover

      Observed ice not discarded between guest stays.

      Correction: Discard all TCS foods and opened non-TCS food items including ice stowed in open containers/bins/tray/bags at guest turnover.

      Code ATCP 72.21(3)

    • Not serious Non-critical

      License posted in public view

      A current license is not posted on the premises in a place visible to the public.

      Correction: Post a current license in the premises in a place visible to the public.

      Code ATCP 72.07(7)

    • Not serious Non-critical Corrected on site

      Guest-provided sanitization - consumer notice signage - provided

      Sanitization signage is not posted or provided.

      Correction: Post or provide signage notifying guests that the utensils and dishware were not sanitized. Provided sani sign at time of the inspection.

      Code ATCP 72.20(6)(e)3.

  2. Aug 18, 2025 Routine · No items found

    No violations cited.

  3. Jun 21, 2024 Routine · No items found

    No violations cited.

  4. Nov 7, 2023 Pre-inspection · 1 non-critical
    • Not serious Non-critical

      PRIVATE WELL-WATER UNSAFE; POTABLE WATER PROVISIONS

      The well water from the well servicing this property has been determined by laboratory analysis to be unsafe per DNR 809 standards.

      Correction: Provide safe potable water from a tested and approved source on a temporary basis until the well is tested safe or a new well is drilled and the water is determined safe. Immediately discontinue use of the well's water supply for drinking, cooking and ice making purposes. Bathing is OK. Provide bottled water and ice supply from an approved source until a safe on-premise water supply is available.

      Code [E] ATCP 72.10 (3)