Found Sessions Time
2009 KLEPPE RD, Saint Germain, WI 54558 · Vilas County
Establishment
- Type
- Lodging (Tourist Rooming House - 1 TRH)
- Inspected by
- Vilas County Public Health
- License / ID
- ASPR-C85HF5
- Status
- Permitted
- Official record
- Vilas County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 8 | 0 |
| 2024 | 1 | 0 | 0 |
| 2023 | 1 | 1 | 0 |
Inspections
-
Oct 20, 2026 Follow Up · No items found
No violations cited.
-
Jul 8, 2026 Routine · 8 non-critical
-
Not serious
Priority Foundation
Smoke alarm installed in each sleeping room
A smoke alarm is not within each sleeping room. The bedroom upstairs and downstairs do not have a smoke alarm.
Correction: Provide a smoke alarm within each sleeping room.
Code ATCP 72.18(11)(b)3.
-
Not serious
Priority Foundation
Guards provided on stairs > 3 risers
Guards are not provided on all open sides of the deck stairs.
Correction: An additional handrail w/ guards shall be provided on all open sides of stairs consisting of more than 3 risers.
Code ATCP 72.18(2)(b)1.
-
Not serious
Priority Foundation
Guard spacing <= 6"
The space between guards, and the space formed between the bottom guard and the deck's elevated walking surface, is more than 6 inches.
Correction: Modify the space between guards, and the space formed between the bottom guard and the decks's elevated walking surface, to be equal to or less than 6 inches.
Code ATCP 72.18(2)(b)3.
-
Not serious
Priority Foundation
Stairs - area formed by riser, tread, bottom guard <= 8"
The triangular area formed by the tread, riser and bottom guard on the deck stairs is more than 8 inches in width.
Correction: Modify the triangular area formed by the tread, riser and bottom guard on the deck stairs to be equal to or less than 8 inches in width.
Code ATCP 72.18(2)(b)5.
-
Not serious
Priority Foundation
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Not serious
Non-critical
License posted in public view
A current license is not posted on the premises in a place visible to the public.
Correction: Post a current license in the premises in a place visible to the public.
Code ATCP 72.07(7)
-
Not serious
Non-critical
Food-contact utensil surfaces - nonabsorbent
The kitchen has wooden utensils. Wooden utensils are an absorbent food-contact utensil/dishware.
Correction: Discontinue use of the food-contact utensil or dishware.
Code ATCP 72.20(5)(f)
-
Not serious
Non-critical
Corrected on site
Guest-provided sanitization - consumer notice signage - provided
Sanitization signage is not posted or provided.
Correction: Post or provide signage notifying guests that the utensils and dishware were not sanitized. Provided signage next to the kitchen sink during inspection.
Code ATCP 72.20(6)(e)3.
-
Not serious
Priority Foundation
-
Jul 7, 2024 Routine · No items found
No violations cited.
-
Jun 6, 2023 Routine · 1 non-critical
-
Not serious
Non-critical
GENERAL MAINTENANCE
Ice cubes were left in the freezer.
Correction: Remove all ice cubes from the unit. Correct by next routine inspection.
Code [C] ATCP 72.15 (1)
-
Not serious
Non-critical
Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.