Fosters Lake House
7566 SOUTHBAY TRL, Saint Germain, WI 54558 · Vilas County
Establishment
- Type
- Lodging (Tourist Rooming House - 1 TRH)
- Inspected by
- Vilas County Public Health
- License / ID
- HSAT-7QWNUN
- Status
- Permitted
- Phone
- (312) 515-3194
- Official record
- Vilas County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 8 | 3 |
| 2025 | 1 | 1 | 0 |
| 2024 | 1 | 0 | 0 |
| 2023 | 1 | 0 | 0 |
Inspections
-
Jul 29, 2026 Routine · 8 non-critical
-
Serious
Critical
Smoke alarms provided
Smoke alarms are not adequately provided within each individually keyed unit.
Correction: Provide smoke alarms within each individually keyed unit at the locations specified in rule.
Code ATCP 72.18(11)(a)
-
Serious
Critical
Smoke alarm maintained - working order; expiration
The smoke alarms are not replaced in accordance with the manufacturer’s date of expiration. Smoke alarms in the upstairs bedroom and one lower bedroom have manufacture dates of 2008.
Correction: Repair or replace the smoke alarm within 10 calendar days.
Code ATCP 72.18(11)(e)
-
Serious
Critical
Carbon monoxide alarm installation - FBA within IKU or sleeping room
A carbon monoxide alarm is not provided outside of each separate sleeping area. Basement bedrooms do not have a carbon monoxide alarm within 21 feet.
Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.
Code ATCP 72.18(12)(b)
-
Not serious
Priority Foundation
Smoke alarm installed on each floor
A smoke alarm is not provided on each floor level at the top of stairways. The top of the stairway does not have a smoke alarm.
Correction: Provide a smoke alarm on each floor level to include a basement or ground floor and at the top of any stairway but excluding crawl spaces and unfinished attics.
Code ATCP 72.18(11)(b)1.
-
Not serious
Priority Foundation
Smoke alarm installed outside each separate sleeping area
A smoke alarm is not provided outside of each separate sleeping area, within 21 feet of any door to a sleeping room. Themain floor does not have a smoke alarm.
Correction: Provide a smoke alarm outside of each separate sleeping area, within 21 feet of any door to a sleeping room.
Code ATCP 72.18(11)(b)2.
-
Not serious
Priority Foundation
Smoke alarm installed in each sleeping room
A smoke alarm is not within each sleeping room. The bedroom with the bunkbeds does not have a smoke alarm.
Correction: Provide a smoke alarm within each sleeping room.
Code ATCP 72.18(11)(b)3.
-
Not serious
Priority Foundation
Bunk beds - 2.5' spacing between beds
A vertical separation of less than 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed was observed. Bed spacing was measured at 26 inches.
Correction: Provide a vertical separation of at least 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed [describe location].
Code ATCP 72.18(3)(d)2.
-
Not serious
Priority Foundation
Building evacuation diagram (TRH) - posted or provided
A building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post a building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Serious
Critical
-
Jul 31, 2025 Routine · 1 non-critical
-
Not serious
Non-critical
UTENSIL SANITIZATION - CLEANING PROCEDURES
Bleach not provided for dish sanitation
Correction: All multi-use utensils must be washed, rinsed and sanitized using approved methods, equipment and chemicals. Provide approved 3 compartment sink or approved commercial dish machine for this purpose. Test sanitizer strength in manual/mechanical methods. Provide means of testing hot water sanitization, if applicable. No utensils for food contact may be washed in a guestroom lavatory.
Code [A] ATCP 72.11 (3)(a)
-
Not serious
Non-critical
-
Jul 16, 2024 Routine · No items found
No violations cited.
-
Jun 27, 2023 Routine · No items found
No violations cited.
Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.