  1. Jun 4, 2026 Routine · 9 non-critical
    • Serious Critical

      General health and safety standard

      There is a deck leading from the kitchen on the upper floor that is currently under construction.

      Correction: Send pictures of completed deck to verify guardrails meet applicable standards.

      Code ATCP 72.15

    • Serious Critical

      Carbon monoxide alarms provided

      A carbon monoxide alarm is not provided anywhere in the lodging facility that also contains a fuel-burning appliance.

      Correction: Provide carbon monoxide alarms at the locations specified in rule.

      Code ATCP 72.18(12)(a)

    • Serious Critical

      Carbon monoxide alarm installation - FBA within IKU or sleeping room

      A carbon monoxide alarm is not provided outside of each separate sleeping area.

      Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room for each floor.

      Code ATCP 72.18(12)(b)

    • Not serious Priority Foundation

      Smoke alarm installed outside each separate sleeping area

      A smoke alarm is not provided outside of each separate sleeping area, within 21 feet of any door to a sleeping room. The upstairs does not have a smoke alarm outside of the master bedroom within 21 feet.

      Correction: Provide a smoke alarm outside of each separate sleeping area, within 21 feet of any door to a sleeping room, for each floor.

      Code ATCP 72.18(11)(b)2.

    • Not serious Priority Foundation

      Smoke alarm installed in each sleeping room

      A smoke alarm is not within each sleeping room. The downstairs bedrooms do not have a smoke alarm.

      Correction: Provide a smoke alarm within each sleeping room.

      Code ATCP 72.18(11)(b)3.

    • Not serious Priority Foundation

      Guard spacing <= 6"

      The space between guards, and the space formed between the bottom guard and the deck outside the front door, is more than 6 inches.

      Correction: Modify the space between guards, and the space formed between the bottom guard and the deck outside of the front door, to be equal to or less than 6 inches.

      Code ATCP 72.18(2)(b)3.

    • Not serious Priority Foundation

      Bunk beds - 2.5' spacing between top bed and ceiling

      A free space of less than 2.5 feet was observed above the mattress of the upper bunk bed in the downstairs bedroom.

      Correction: Provide a free space of at least 2.5 feet above the mattress of the upper bunk bed in the downstairs bedroom.

      Code ATCP 72.18(3)(d)3.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram does not match the floor plan of the building. Provide a diagram for both levels as well.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

    • Not serious Non-critical

      Food-contact utensil surfaces - nonabsorbent

      The wooden utensils/cutting boards in kitchen are absorbent.

      Correction: Discontinue use of wooden utensils/cutting boards.

      Code ATCP 72.20(5)(f)

  2. Jun 10, 2025 Pre-inspection · No items found

    No violations cited.