RecordWell Data

Lake Forest - Unit #102

1534 LAKE FOREST LN, Eagle River, WI 54521 · Vilas County

15cited violations
2serious tier
2inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Vilas County Public Health
License / ID
BHAA-DUYK7L
Status
Permitted
Phone
(319) 551-4666
Official record
Vilas County Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20262152

Inspections

  1. Jun 25, 2026 Follow Up · 6 non-critical, 6 repeat
    • Not serious Priority Foundation Repeat

      Guards provided on stairs > 3 risers

      Guards with gaps of 6 inches or less are not provided on all open sides of stairs leading to shared community deck attached to the building.

      Correction: Guards shall be provided on all open sides of stairs consisting of more than 3 risers, close enough together that gaps are less than 6 inches.

      Code ATCP 72.18(2)(b)1.

    • Not serious Priority Foundation Repeat

      Guards provided > 30" fall

      The shared deck is not provided with guards on all open sides that are elevated more than 30 inches above the floor or grade.

      Correction: Provide guards on all open sides of the shared deck that are elevated more than 30 inches above the floor or grade.

      Code ATCP 72.18(2)(b)2.

    • Not serious Priority Foundation Repeat

      Guard spacing <= 6"

      The space formed between the bottom guard and the patio door deck, is more than 6 inches.

      Correction: Modify the space between guards, and the space formed between the bottom guard and the patio door deck to be equal to or less than 6 inches.

      Code ATCP 72.18(2)(b)3.

    • Not serious Priority Foundation Repeat

      Guard height >= 36" - elevated surfaces

      The guard height is less than 36 inches on deck as measured vertically above the adjacent walking surface. Measured guard height was 34.75 inches. The space between the bottom guard and the walking surface is greater than 6 inches. Measured gap height was 7 inches.

      Correction: Modify the guard height to be equal to or greater than 36 inches on deck as measured vertically above the adjacent walking surface. Modify the guard on the bottom to have a gap of 6 inches or less.

      Code ATCP 72.18(2)(b)6.a.

    • Not serious Priority Foundation Repeat

      Bunk beds - 2.5' spacing between beds

      A vertical separation of less than 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed was observed in the upstairs bedroom. Separation of 2 feet 1 inch was measured between top of mattress and bottom of uppder bunk.

      Correction: Provide a vertical separation of at least 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed [describe location].

      Code ATCP 72.18(3)(d)2.

    • Not serious Non-critical Repeat

      Food-contact utensil surfaces - nonabsorbent

      The surfaces of the wooden cutting boards and wooden spoons are absorbent.

      Correction: Discontinue use of the wooden food-contact utensil or dishware.

      Code ATCP 72.20(5)(f)

  2. Jun 12, 2026 Pre-inspection · 9 non-critical
    • Serious Critical

      Carbon monoxide alarms provided

      A carbon monoxide alarm is not provided anywhere in the lodging facility that also contains a fuel-burning appliance.

      Correction: Provide carbon monoxide alarms at the locations specified in rule.

      Code ATCP 72.18(12)(a)

    • Serious Critical

      Carbon monoxide alarm installation - FBA within IKU or sleeping room

      A carbon monoxide alarm is not provided outside of each separate sleeping area.

      Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.

      Code ATCP 72.18(12)(b)

    • Not serious Priority Foundation

      Guards provided on stairs > 3 risers

      Guards with gaps of 6 inches or less are not provided on all open sides of stairs leading to shared community deck attached to the building.

      Correction: Guards shall be provided on all open sides of stairs consisting of more than 3 risers, close enough together that gaps are less than 6 inches.

      Code ATCP 72.18(2)(b)1.

    • Not serious Priority Foundation

      Guards provided > 30" fall

      The shared deck is not provided with guards on all open sides that are elevated more than 30 inches above the floor or grade.

      Correction: Provide guards on all open sides of the shared deck that are elevated more than 30 inches above the floor or grade.

      Code ATCP 72.18(2)(b)2.

    • Not serious Priority Foundation

      Guard spacing <= 6"

      The space formed between the bottom guard and the patio door deck, is more than 6 inches.

      Correction: Modify the space between guards, and the space formed between the bottom guard and the patio door deck to be equal to or less than 6 inches.

      Code ATCP 72.18(2)(b)3.

    • Not serious Priority Foundation

      Guard height >= 36" - elevated surfaces

      The guard height is less than 36 inches on deck as measured vertically above the adjacent walking surface. Measured guard height was 34.75 inches. The space between the bottom guard and the walking surface is greater than 6 inches. Measured gap height was 7 inches.

      Correction: Modify the guard height to be equal to or greater than 36 inches on deck as measured vertically above the adjacent walking surface. Modify the guard on the bottom to have a gap of 6 inches or less.

      Code ATCP 72.18(2)(b)6.a.

    • Not serious Priority Foundation

      Bunk beds - 2.5' spacing between beds

      A vertical separation of less than 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed was observed in the upstairs bedroom. Separation of 2 feet 1 inch was measured between top of mattress and bottom of uppder bunk.

      Correction: Provide a vertical separation of at least 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed [describe location].

      Code ATCP 72.18(3)(d)2.

    • Not serious Non-critical

      Carbon monoxide alarm UL certified or equivalent

      There is no carbon monoxide alarm with the UL listing mark or a similar mark from an independent product safety certification organization

      Correction: Provide carbon monoxide alarms that have UL listing marks or a similar marks from an independent product safety certification organization.

      Code ATCP 72.18(12)(f)

    • Not serious Non-critical

      Food-contact utensil surfaces - nonabsorbent

      The surfaces of the wooden cutting boards and wooden spoons are absorbent.

      Correction: Discontinue use of the wooden food-contact utensil or dishware.

      Code ATCP 72.20(5)(f)

Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.