7cited violations
3serious tier
4inspections

Establishment

Type
Lodging (Tourist Rooming House - 2 - 4 TRH)
Inspected by
Vilas County Public Health
License / ID
TAYL-AYTHET
Status
Permitted
Phone
(262) 689-2563
Official record
Vilas County Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026163
2025110
2024100
2023100

Inspections

  1. Sep 2, 2026 Routine · 6 non-critical
    • Serious Critical

      Carbon monoxide alarm installation - FBA within IKU or sleeping room

      A carbon monoxide alarm is not provided outside of each separate sleeping area.

      Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom. Install a carbon monoxide alarm in the center common area between the upstairs sleeping rooms and in the basement couch sleeping area.

      Code ATCP 72.18(12)(b)

    • Serious Critical

      Second floor sleeping room - 2 exits provided

      The second floor used for sleeping area upstairs/left was not provided with at least 2 separate exits.

      Correction: Provide at least 2 separate exits from the second floor used for sleeping or discontinue sleeping from that location.

      Code ATCP 72.18(4)(c)

    • Serious Critical

      Windows used for exiting - 20 inches x 24 inches

      The upstairs/left window used for exiting has a casement window opening of only 12 inches.

      Correction: Provide a window opening at least 20 inches by 24 inches irrespective of the height or width, or provide a different exit, or discontinue sleeping from that location.

      Code ATCP 72.18(4)(g)2.

    • Not serious Priority Foundation

      Smoke alarm installed on each floor

      A smoke alarm is not provided on each floor level. The basement does not have a smoke alarm.

      Correction: Provide a smoke alarm on each floor level to include a basement or ground floor and at the top of any stairway but excluding crawl spaces and unfinished attics.

      Code ATCP 72.18(11)(b)1.

    • Not serious Priority Foundation

      Bunk beds - 2.5' spacing between top bed and ceiling

      A free space of less than 2.5 feet was observed above the mattress of the upper bunk beds in the sleeping area upstairs/left.

      Correction: Provide a free space of at least 2.5 feet above the mattress of the upper bunk beds in the sleeping area. Install thinner mattresses or remove top bunk.

      Code ATCP 72.18(3)(d)3.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

  2. Jul 19, 2025 Routine · 1 non-critical
    • Not serious Non-critical

      GENERAL MAINTENANCE

      The small loft area located in one of the upstairs bedrooms has a handrail that doesn't meet the required 36-inch height.

      Correction: Add additional guard railings to increase the height of this handrail to at least 36-inches, or restrict access to this loft area to guests as soon as possible.

      Code [C] ATCP 72.15 (1)

  3. Aug 8, 2024 Routine · No items found

    No violations cited.

  4. Oct 4, 2023 Routine · No items found

    No violations cited.

Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.