Owl's View Lakehouse
6105 W BUCKATABON RD, Conover, WI 54519 · Vilas County
Establishment
- Type
- Lodging (Tourist Rooming House - 1 TRH)
- Inspected by
- Vilas County Public Health
- License / ID
- BHAA-DM8P77
- Status
- Permitted
- Phone
- (715) 999-8726
- Official record
- Vilas County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 5 | 1 |
| 2025 | 2 | 3 | 0 |
Inspections
-
Oct 13, 2026 Routine · 5 non-critical
-
Serious
Critical
Smoke alarm maintained - working order; expiration
The smoke alarm in the basement is expired, replaced in accordance with the manufacturer’s date of expiration.
Correction: Repair or replace the smoke alarm within 3 calendar days.
Code ATCP 72.18(11)(e)
-
Not serious
Priority Foundation
Smoke alarm installed on each floor
A smoke alarm is not provided at the top of the basement stairs.
Correction: Provide a smoke alarm on each floor level to include a basement or ground floor and at the top of any stairway but excluding crawl spaces and unfinished attics.
Code ATCP 72.18(11)(b)1.
-
Not serious
Priority Foundation
Bunk beds - 2.5' spacing between beds
A vertical separation of less than 2.5 feet (30") measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed was observed. The current space is 23".
Correction: Provide a vertical separation of at least 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed.
Code ATCP 72.18(3)(d)2.
-
Not serious
Priority Foundation
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Not serious
Non-critical
License posted in public view
A current license is not posted on the premises in a place visible to the public.
Correction: Post a current license in the premises in a place visible to the public.
Code ATCP 72.07(7)
-
Serious
Critical
-
Feb 13, 2026 Follow Up · No items found
No violations cited.
-
Oct 30, 2025 Follow Up · 1 non-critical
-
Not serious
Non-critical
SMOKE DETECTORS - REQUIREMENT
Smoke detectors are absent or not in working order in bedrooms.
Correction: Provide operational smoke detectors in all sleeping rooms (by date 1/25/2026) and required locations. Replace hallway ceiling smoke dector.
Code ATCP 72.14 (2) (c)
-
Not serious
Non-critical
-
Oct 1, 2025 Pre-inspection · 2 non-critical
-
Not serious
Non-critical
SMOKE DETECTORS - REQUIREMENT
Smoke detectors are absent or not in working order in bedrooms.
Correction: Provide operational smoke detectors in all sleeping rooms and required locations.
Code ATCP 72.14 (2) (c)
-
Not serious
Non-critical
GENERAL MAINTENANCE
Guard spacing on staircase to basement exceeds 6" maximum.
Correction: All elevated surfaces in interior and exterior areas of a lodging facility shall be provided with guards on all open sides that are elevated more than 30 inches above the floor or grade, including lofts, open sides of landings, platforms, decks, balconies or porches that are a part of or attached to the lodging facility. Guard spacing must be equal to or less than 6 inches. Install additional guar
Code [C] ATCP 72.15 (1)
-
Not serious
Non-critical
Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.