Elberts Resort - Deerpath
1052 ELBERT RD, Saint Germain, WI 54558 · Vilas County
Establishment
- Type
- Lodging (Tourist Rooming House - 1 TRH)
- Inspected by
- Vilas County Public Health
- License / ID
- HSAT-7QX4PM
- Status
- Permitted
- Phone
- (630) 209-2500
- Official record
- Vilas County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 7 | 4 |
| 2025 | 1 | 0 | 0 |
| 2024 | 1 | 0 | 0 |
| 2023 | 1 | 0 | 0 |
Inspections
-
Oct 29, 2026 Routine · 7 non-critical
-
Serious
Critical
Carbon monoxide alarm installation - FBA within IKU or sleeping room
A carbon monoxide alarm is not provided outside each separate sleeping area. The existing carbon monoxide alarm is mounted at the top of the stairs and does not provide coverage for the basement sleeping area.
Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.
Code ATCP 72.18(12)(b)
-
Serious
Critical
Basement or ground floor sleeping room - 2 exits provided
The basement or ground floor bedroom at the bottom of the stairs, used for sleeping was not provided with at least 2 separate exits.There is only one means of egress to the upper floor, and the room does not have an egress window.
Correction: Provide at least 2 separate exits from the basement or ground floor bedroom used for sleeping or discontinue sleeping from that that bedroom.
Code ATCP 72.18(4)(ar)
-
Serious
Critical
Second floor sleeping room - 2 exits provided
The second floor used for sleeping was not provided with at least 2 separate exits. A permanent wall has been constructed, enclosing approximately 50% of the loft opening to the floor below and effectively creating a second-floor room. The room does not have a window.
Correction: Provide at least 2 separate exits from the second floor used for sleeping or discontinue sleeping from that floor.
Code ATCP 72.18(4)(c)
-
Serious
Critical
Windows used for exiting - 20 inches x 24 inches
The basement bedroom window used for exiting, does not meet the required opening measurements of 20 inches x 24 inches.
Correction: Provide a window opening at least 20 inches by 24 inches irrespective of the height or width, or provide a different exit, or discontinue sleeping from that floor.
Code ATCP 72.18(4)(g)2.
-
Not serious
Priority Foundation
Stairs - area formed by riser, tread, bottom guard <= 8"
The triangular area formed by the tread, riser and bottom guard on the stairs leading to the second floor is more than 8 inches in width.
Correction: Modify the triangular area formed by the tread, riser and bottom guard to be equal to or less than 8 inches in width.
Code ATCP 72.18(2)(b)5.
-
Not serious
Priority Foundation
Guard height >= 36" - elevated surfaces
The guard height is less than 36 inches on second floor guards as measured vertically above the adjacent walking surface.
Correction: Modify the guard height to be equal to or greater than 36 inches on the second floor guards as measured vertically above the adjacent walking surface.
Code ATCP 72.18(2)(b)6.a.
-
Not serious
Priority Foundation
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Serious
Critical
-
Sep 4, 2025 Routine · No items found
No violations cited.
-
Jul 8, 2024 Routine · No items found
No violations cited.
-
Jul 1, 2023 Routine · No items found
No violations cited.
Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.