Inspections

  1. Jul 9, 2026 Routine · 3 non-critical
    • Serious Critical

      Carbon monoxide alarm installation - FBA within IKU or sleeping room

      A carbon monoxide alarm is not provided outside the separate sleeping area of the entryway.

      Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.

      Code ATCP 72.18(12)(b)

    • Not serious Priority Foundation

      Smoke alarm installed in each sleeping room

      A smoke alarm is not within each sleeping room. The entryway (with futon/bed) and office (with futon) do not have a smoke alarms.

      Correction: Provide a smoke alarm within each sleeping room.

      Code ATCP 72.18(11)(b)3.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

  2. Jul 12, 2025 Routine · No items found

    No violations cited.

  3. Jun 22, 2024 Routine · No items found

    No violations cited.

  4. Jun 14, 2023 Pre-inspection · 1 non-critical
    • Not serious Non-critical

      GENERAL MAINTENANCE

      Guard spacing surrounding basement opening are not 4 inches, measure 6.5inch spacing

      Correction: Fill guard spacing so that the opening is no more than 4 inches. Permit will be held until correction proof is sent to skokg@uwosh.edu

      Code [C] ATCP 72.15 (1)