  1. Oct 13, 2026 Follow Up · 2 non-critical, 2 repeat
    • Not serious Priority Foundation Repeat

      Bunk beds - 2.5' spacing between beds

      A vertical separation of less than 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed was observed.

      Correction: Provide a vertical separation of at least 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed.

      Code ATCP 72.18(3)(d)2.

    • Not serious Priority Foundation Repeat

      Bunk beds - guards 5" above mattress

      The top of the guard was less than 5 inches above the top of the mattress of the upper bunk bed.

      Correction: Reconstruct the top guard or install a thinner mattress to provide at least 5 inches above the top of the mattress.

      Code ATCP 72.18(3)(d)4.a.

  2. Jul 30, 2026 Routine · 8 non-critical
    • Serious Critical

      Slip-resistant flooring in shower and bathtubs

      The showers and bathtubs are not provided with slip-resistant flooring or materials.

      Correction: Slip-resistant flooring or materials shall be provided in all shower and bathtub basins.

      Code ATCP 72.17(5)(f)

    • Serious Critical

      Carbon monoxide alarm maintained - working order; expiration

      The carbon monoxide alarms are not replaced in accordance with the manufacturer’s date of expiration.

      Correction: Repair or replace the carbon monoxide alarm within 5 calendar days.

      Code ATCP 72.18(12)(h)

    • Not serious Priority Foundation

      Smoke alarm installed in each sleeping room

      A smoke alarm is not within each sleeping room.

      Correction: Provide a smoke alarm within each sleeping room.

      Code ATCP 72.18(11)(b)3.

    • Not serious Priority Foundation

      Bunk beds - 2.5' spacing between beds

      A vertical separation of less than 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed was observed.

      Correction: Provide a vertical separation of at least 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed.

      Code ATCP 72.18(3)(d)2.

    • Not serious Priority Foundation

      Bunk beds - guards 5" above mattress

      The top of the guard was less than 5 inches above the top of the mattress of the upper bunk bed.

      Correction: Reconstruct the top guard or install a thinner mattress to provide at least 5 inches above the top of the mattress.

      Code ATCP 72.18(3)(d)4.a.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

    • Not serious Non-critical

      Food-contact utensil surfaces - nonabsorbent

      Kitchen utensils wirh absorbent surfaces were observed in the kitchen.

      Correction: Discontinue use of the food-contact utensil or dishware.

      Code ATCP 72.20(5)(f)

    • Not serious Non-critical

      Garbage containers - sufficient number

      There is not a sufficient number of containers to hold garbage.

      Correction: Provide a sufficient number of containers to hold garbage and refuse until disposal.

      Code ATCP 72.23(1)

  3. Aug 14, 2025 Routine · 1 non-critical
    • Not serious Non-critical

      PERMIT NOT DISPLAYED IN PUBLIC VIEW

      Permit is not displayed conspicuously to the public.

      Correction: Post the current year's permit in a conspicuous location to the public as soon as possible.

      Code ATCP 72.04 (7)

  4. Aug 28, 2024 Re-inspection · 1 non-critical
    • Not serious Non-critical

      PRIVATE WELL-WATER UNSAFE; POTABLE WATER PROVISIONS

      The well water from the well servicing this property has been determined by laboratory analysis to be unsafe per DNR 809 standards. Re-sample tested Positive for Coliform Bacteria.

      Correction: Provide safe potable water from a tested and approved source on a temporary basis until the well is tested safe or a new well is drilled and the water is determined safe. Immediately discontinue use of the well's water supply for drinking, cooking and ice making purposes. Bathing is OK. Provide bottled water and ice supply from an approved source until a safe on-premise water supply is available.

      Code [E] ATCP 72.10 (3)

  5. Aug 16, 2024 Routine · No items found

    No violations cited.

  6. Aug 31, 2023 Routine · No items found

    No violations cited.