Crazy Loon Lodge And Cla Rie Cottage
1578 BRANDENBURG RD, Saint Germain, WI 54558 · Vilas County
Establishment
- Type
- Lodging (Tourist Rooming House - 2 - 4 TRH)
- Inspected by
- Vilas County Public Health
- License / ID
- ASPR-9YEKQY
- Status
- Permitted
- Official record
- Vilas County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 9 | 3 |
| 2024 | 1 | 0 | 0 |
| 2023 | 1 | 0 | 0 |
Inspections
-
Jun 18, 2026 Re-inspection · No items found
No violations cited.
-
Mar 23, 2026 Routine · 9 non-critical
-
Serious
Critical
Smoke alarm maintained - working order; expiration
The smoke alarms in all locations were not in working order, expired or would not test. Rreplaced in accordance with the manufacturer’s date of expiration.
Correction: Repair or replace the smoke alarm within 5 calendar days.
Code ATCP 72.18(11)(e)
-
Serious
Critical
Carbon monoxide alarm installation - FBA within IKU or sleeping room
A carbon monoxide alarm is not provided outside of each separate sleeping area.
Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.
Code ATCP 72.18(12)(b)
-
Serious
Critical
Carbon monoxide alarm maintained - working order; expiration
The carbon monoxide alarm in basement is not maintained in working order, replaced in accordance with the manufacturer’s date of expiration.
Correction: Repair or replace the carbon monoxide alarm within 5 calendar days.
Code ATCP 72.18(12)(h)
-
Not serious
Priority Foundation
Guards provided > 30" fall
The open side of the deck between the benches, is not provided with guards on all open sides that are elevated more than 30 inches above the floor or grade.
Correction: Provide guards on all open sides of the deck, balcony that are elevated more than 30 inches above the floor or grade or bring grade around deck to <30".
Code ATCP 72.18(2)(b)2.
-
Not serious
Priority Foundation
Guard spacing <= 6"
The space between guards, on the stairs leading to the basement, is more than 6 inches.
Correction: Modify the space between guards, to be equal to or less than 6 inches.
Code ATCP 72.18(2)(b)3.
-
Not serious
Priority Foundation
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Not serious
Non-critical
License posted in public view
A current license is not posted on the premises in a place visible to the public.
Correction: Post a current license in the premises in a place visible to the public.
Code ATCP 72.07(7)
-
Not serious
Non-critical
Sleeping rooms maintained in good repair
The ceiling light covers in the lower bedroom is not maintained in good repair cover cracked.
Correction: Maintain all sleeping rooms in good repair.
Code ATCP 72.19(1)(a)2.
-
Not serious
Non-critical
Common areas maintained in a clean condition
The carpet on stairs to basement is stained. The ceiling tiles in the basement are bowing and in need of repair or replacemnt
Correction: Maintain all common areas in a clean/safe condition.
Code ATCP 72.19(1)(b)2
-
Serious
Critical
-
Aug 12, 2024 Routine · No items found
No violations cited.
-
Jul 19, 2023 Routine · No items found
No violations cited.
Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.