South Bay Resort - Antler Crossing
7508 CARDELLA LN, Saint Germain, WI 53913 · Vilas County
Establishment
- Type
- Lodging (Tourist Rooming House - 1 TRH)
- Inspected by
- Vilas County Public Health
- License / ID
- BJOA-8MEKYK
- Status
- Permitted
- Phone
- (608) 963-4193
- Official record
- Vilas County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 7 | 2 |
| 2025 | 1 | 1 | 0 |
| 2024 | 1 | 0 | 0 |
| 2023 | 1 | 0 | 0 |
Inspections
-
Mar 17, 2026 Routine · 7 non-critical
-
Serious
Critical
Smoke alarm maintained - working order; expiration
The smoke alarms (2002) in the sleeping rooms are not in accordance with the manufacturer’s date of expiration 10 year life.
Correction: Repair or replace the smoke alarm within 5 calendar days.
Code ATCP 72.18(11)(e)
-
Serious
Critical
Carbon monoxide alarm installation - FBA within IKU or sleeping room
A carbon monoxide alarm is not provided in the bunk bed sleeping room with a fuel-burning appliance.
Correction: Provide a carbon monoxide alarm in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.
Code ATCP 72.18(12)(b)
-
Not serious
Priority Foundation
Carbon monoxide alarm installation - FBA outside IKU
A carbon monoxide alarm is not provided outside of each separate sleeping area within the individually keyed unit..
Correction: Provide carbon monoxide alarm outside of each separate sleeping areas near the wood stove. The current installed CO alarm in the dining room could be moved closer in proximity to these sleeping rooms.
Code ATCP 72.18(12)(c)
-
Not serious
Priority Foundation
Bunk beds - 2.5' spacing between beds
A vertical separation of less than 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed was observed in sleeping room with a FBA.
Correction: Provide a vertical separation of at least 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed.
Code ATCP 72.18(3)(d)2.
-
Not serious
Priority Foundation
Bunk beds - 2.5' spacing between top bed and ceiling
A free space of less than 2.5 feet was observed above the mattress of the upper bunk bed sleeping room.
Correction: Provide a free space of at least 2.5 feet above the mattress of the upper bunk bed.
Code ATCP 72.18(3)(d)3.
-
Not serious
Priority Foundation
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Not serious
Non-critical
License posted in public view
A current license is not posted on the premises in a place visible to the public.
Correction: Post a current license in the premises in a place visible to the public.
Code ATCP 72.07(7)
-
Serious
Critical
-
Jun 17, 2025 Routine · 1 non-critical
-
Not serious
Non-critical
WINDOW SCREENING
Holes in screens.
Correction: Provide screening on all windows that can be opened to the outside.
Code ATCP 72.14 (2) (e)
-
Not serious
Non-critical
-
Jun 20, 2024 Routine · No items found
No violations cited.
-
May 31, 2023 Routine · No items found
No violations cited.
Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.