RecordWell Data

Lost Paradise

7833 N LOST LAKE DR, Saint Germain, WI 54558 · Vilas County

9cited violations
2serious tier
4inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Vilas County Public Health
License / ID
TAYL-B64JZB
Status
Permitted
Phone
(319) 325-2829
Official record
Vilas County Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026171
2025111
2024110
2023100

Inspections

  1. Sep 9, 2026 Routine · 7 non-critical
    • Serious Critical

      Smoke alarms provided

      Smoke alarms are not adequately provided within each individually keyed unit.

      Correction: Provide smoke alarms within each individually keyed unit at the locations specified in rule.

      Code ATCP 72.18(11)(a)

    • Not serious Priority Foundation

      Smoke alarm installed in each sleeping room

      A smoke alarm is not within each sleeping room. The bedrooms do not have smoke alarms.

      Correction: Provide a smoke alarm within each sleeping room.

      Code ATCP 72.18(11)(b)3.

    • Not serious Priority Foundation

      Guard spacing <= 6"

      The space between guards, and the space formed between the bottom guard and the porch, is more than 6 inches. Spacing between horizontal guards measured at 12.5 inches.

      Correction: Modify the space between guards, and the space formed between the bottom guard and the porch, to be equal to or less than 6 inches.

      Code ATCP 72.18(2)(b)3.

    • Not serious Priority Foundation

      Guard height >= 36" - elevated surfaces

      The guard height is less than 36 inches on the porch as measured vertically above the adjacent walking surface. The railing is interrupted for a low open bench on the side of the porch. This bench does not have any back rail that reaches 36 inches.

      Correction: Add a rail so that the guard height is equal to or greater than 36 inches as measured vertically above the adjacent walking surface.

      Code ATCP 72.18(2)(b)6.a.

    • Not serious Priority Foundation

      Bunk beds - 2.5' spacing between beds

      A vertical separation of less than 30 inches measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed was observed in the bunk bed in the left bedroom.

      Correction: Provide a vertical separation of at least 30 inches measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed or remove the top bunk.

      Code ATCP 72.18(3)(d)2.

    • Not serious Priority Foundation

      Bunk beds - guards 5" above mattress

      The top of the guard was less than 5 inches above the top of the mattress of the upper bunk bed in the bedroom on the right.

      Correction: Remove pad rom mattress to make it thinner, or install a thinner mattress or reconstruct the top guard to provide at least 5 inches above the top of the mattress.

      Code ATCP 72.18(3)(d)4.a.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

  2. Jul 18, 2025 Routine · 1 critical
    • Serious Critical

      GENERAL MAINTENANCE

      Porch guardrail and bunk beds are not up to code.

      Correction: Maintained establishment in a manner conducive to the health, comfort and safety of its guests. All elevated surfaces in interior and exterior structures shall be provided with guards on all open sides that are elevated more than 30 inches above the floor or grade, including lofts, open sides of landings, platforms, decks, balconies or porches that are a part of or attached to the lodging structur

      Code [C] ATCP 72.15 (1)

  3. Jul 20, 2024 Routine · 1 non-critical
    • Not serious Non-critical

      TOP BUNK-MISSING RAILS

      Top bunk railings for both bunk beds are not at least 5 inches above the top of the mattress.

      Correction: Install railings that are in compliance with 16 CFR 1513 prior to next annual inspection..

      Code Wisconsin Statute 97.02

  4. Jun 26, 2023 Routine · No items found

    No violations cited.

Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.