Dillman's Bay Resort - Hilltop Cabin, 9a & 9b
13253 DILLMANMS WAY, Lac Du Flambeau, WI 54538 · Vilas County
Establishment
- Type
- Lodging (Tourist Rooming House - 2 - 4 TRH)
- Inspected by
- Vilas County Public Health
- License / ID
- HSAT-7QWJ9U
- Status
- Permitted
- Phone
- (262) 339-9345
- Official record
- Vilas County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 11 | 5 |
| 2024 | 1 | 0 | 0 |
| 2023 | 1 | 0 | 0 |
Inspections
-
Sep 15, 2026 Pre-inspection · 10 non-critical
-
Serious
Critical
Carbon monoxide alarms provided
A carbon monoxide alarm is not provided anywhere in the lodging facility that also contains a fuel-burning appliance.
Correction: Provide carbon monoxide alarms at the locations specified in rule.
Code ATCP 72.18(12)(a)
-
Serious
Critical
Carbon monoxide alarm installation - FBA within IKU or sleeping room
A carbon monoxide alarm is not provided outside of each separate sleeping area.
Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.
Code ATCP 72.18(12)(b)
-
Serious
Critical
Carbon monoxide alarm installation - FBA within IKU or sleeping room
A carbon monoxide alarm is not provided in the sleeping room with the hot water heater located in the sleeping room closet.
Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.
Code ATCP 72.18(12)(b)
-
Serious
Critical
Second floor sleeping room - 2 exits provided
The second floor used for sleeping was not provided with at least 2 separate exits.
Correction: Provide at least 2 separate exits from the second floor used for sleeping or discontinue sleeping from that floor.
Code ATCP 72.18(4)(c)
-
Serious
Critical
Windows used for exiting - 20 inches x 24 inches
The second floor windows used for exiting do not meet window egress requirements. Current opening width of 14".
Correction: Provide a window opening at least 20 inches by 24 inches irrespective of the height or width, or provide a different exit, or discontinue sleeping from that floor.
Code ATCP 72.18(4)(g)2.
-
Not serious
Priority Foundation
Smoke alarm installed in each sleeping room
A smoke alarm is not within each sleeping room. The second floor sleeing rooms do not have a smoke alarm.
Correction: Provide a smoke alarm within each sleeping room.
Code ATCP 72.18(11)(b)3.
-
Not serious
Priority Foundation
Guard height >= 36" - elevated surfaces
The guard height is less than 36 inches on the loft railing as measured vertically above the adjacent walking surface.
Correction: Modify the guard height to be equal to or greater than 36 inches on the loft railing as measured vertically above the adjacent walking surface or restrict guest access.
Code ATCP 72.18(2)(b)6.a.
-
Not serious
Priority Foundation
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Not serious
Priority Foundation
Guest-provided sanitization - sanitizer provided
A chemical sanitizer for utensils is not provided.
Correction: The chemical sanitizer must be available or made available upon request.
Code ATCP 72.20(6)(e)4.
-
Not serious
Non-critical
Ceiling height >= 7'
At least 50 percent of the second floor sleeping room’s floor area does not have a ceiling height of at least 7 feet. Measurement/peak 6' 7".
Correction: Remove beds, restrict guest use/lock doors if the beds are left in the rooms or modify ceiling to gain ceiling height requirement.
Code ATCP 72.18(3)(a)
-
Not serious
Non-critical
Nonabsorbent mattress cover or mattress surface
The mattresses are not provided with a nonabsorbent mattress protector that covers the entire sleeping surface.
Correction: Provide a nonabsorbent mattress protector that covers the entire sleeping surface or have an easily cleanable nonabsorbent mattress surface.
Code ATCP 72.20(8)(d)
-
Serious
Critical
-
Aug 5, 2024 Routine · No items found
No violations cited.
-
Sep 6, 2023 Routine · No items found
No violations cited.
Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.