RecordWell Data

Shorewood Getaway

5125 SHOREWOOD ACRES DR, Eagle River, WI 54521 · Vilas County

13cited violations
4serious tier
4inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Vilas County Public Health
License / ID
ASPR-CCZG2J
Status
Permitted
Phone
(608) 495-0883
Official record
Vilas County Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026183
2025110
2024121
2023120

Inspections

  1. Aug 3, 2026 Routine · 8 non-critical
    • Serious Critical

      Smoke alarms provided

      Smoke alarms are not provided within each individually keyed unit.

      Correction: Provide smoke alarms within each individually keyed unit at the locations specified in rule.

      Code ATCP 72.18(11)(a)

    • Serious Critical

      Smoke alarm maintained - working order; expiration

      The smoke alarm at the top of the stairs/upstairs hallway is not maintained in working order, replaced in accordance with the manufacturer’s date of expiration.

      Correction: Repair or replace the smoke alarm within 5 calendar days.

      Code ATCP 72.18(11)(e)

    • Serious Critical

      Carbon monoxide alarm installation - FBA within IKU or sleeping room

      A carbon monoxide alarm is not provided outside of each separate sleeping area.

      Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.

      Code ATCP 72.18(12)(b)

    • Not serious Priority Foundation

      Smoke alarm installed outside each separate sleeping area

      A smoke alarm is not provided outside of each separate sleeping area, within 21 feet of any door to a sleeping room. The basement does not have a smoke alarm outside of the sleeping room.

      Correction: Provide a smoke alarm outside of each separate sleeping area, within 21 feet of any door to a sleeping room.

      Code ATCP 72.18(11)(b)2.

    • Not serious Priority Foundation

      Bunk beds - 2.5' spacing between top bed and ceiling

      A free space of less than 2.5 feet was observed above the mattress of the upper bunk bed in the upstairs bunk rooms.

      Correction: Provide a free space of at least 2.5 feet above the mattress of the upper bunk bed in both upstairs bunk rooms.

      Code ATCP 72.18(3)(d)3.

    • Not serious Priority Foundation

      Bunk beds - 3.5" spacing between mattress and bottom guard

      The bottom of the guard is more than 3.5 inches above the top of the upper bunk bed frame in the both upstairs bunk rooms.

      Correction: Reconstruct the top guard or install a thicker mattress to provide no more than 3.5 inches between the guard and upper bunk bed frame.

      Code ATCP 72.18(3)(d)4.b.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

    • Not serious Non-critical

      License posted in public view

      A current license is not posted on the premises in a place visible to the public.

      Correction: Post a current license in the premises in a place visible to the public.

      Code ATCP 72.07(7)

  2. Jun 5, 2025 Routine · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      GENERAL MAINTENANCE

      Downstairs basement steps have a large gap between the handrail and base of the steps of about 27-inches.

      Correction: Add additional guard rails between the handrail and base of the steps within 90 days, so there is not a gap in space greater than 6-inches maximum. This is the second inspection that this violation has been noted. IF not corrected by date given below, there will be a reinspection fee charge.

      Code [C] ATCP 72.15 (1)

  3. Jun 4, 2024 Routine · 1 critical, 1 non-critical
    • Not serious Non-critical

      PERMIT NOT DISPLAYED IN PUBLIC VIEW

      Current permit is not displayed conspicuously to the public.

      Correction: Post the current permit in a conspicuous location to the public. Correct by next routine inspection.

      Code ATCP 72.04 (7)

    • Serious Critical

      GENERAL MAINTENANCE

      Guards are not present on stairs leading to basement, posing a safety risk for guests.

      Correction: Install guards on stairs leading into basement to ensure safety of guests or restrict access to basement. Submit proof of installation of guards up to code within 90 days to staff.camaratoje86@uwosh.edu or (715)525-9804 before 09/03/2024.

      Code [C] ATCP 72.15 (1)

  4. May 22, 2023 Routine · 2 non-critical
    • Not serious Non-critical

      CARBON MONOXIDE DETECTOR - POWER SOURCE

      The carbon monoxide detector in the upstairs hallway was detemined to have insufficient power. When tested no light or sound was observed.

      Correction: Provide an active power source or replace batteries in the carbon monoxide detector. Please correct by next annual inspection.

      Code [B] ATCP 72.145 (4)(a)

    • Not serious Non-critical

      GENERAL MAINTENANCE

      The left upstairs screen door has a few small holes.

      Correction: Maintained establishment in a manner conducive to the health, comfort and safety of its guests. Patch or replace screen door as to prevent insects from getting in. Please correct by next annual inspection.

      Code [C] ATCP 72.15 (1)

Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.