7cited violations
1serious tier
4inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Vilas County Public Health
License / ID
ASPR-DABR5V
Status
Permitted
Phone
(715) 439-5037
Official record
Vilas County Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026371
2024100

Inspections

  1. Jul 21, 2026 Follow Up · No items found

    No violations cited.

  2. Jul 15, 2026 Routine · 4 non-critical
    • Serious Critical

      Smoke alarms provided

      Smoke alarms are not adequately provided within each individually keyed unit.

      Correction: Provide smoke alarms within each individually keyed unit at the locations specified in rule.

      Code ATCP 72.18(11)(a)

    • Not serious Priority Foundation

      Smoke alarm installed outside each separate sleeping area

      A smoke alarm is not provided outside of each separate sleeping area, within 21 feet of any door to a sleeping room. The area outside the bedrooms does not have a smoke alarm.

      Correction: Provide a smoke alarm outside of each separate sleeping area, within 21 feet of any door to a sleeping room.

      Code ATCP 72.18(11)(b)2.

    • Not serious Priority Foundation

      Smoke alarm installed in each sleeping room

      A smoke alarm is not within each sleeping room. The space with a futon used for sleeping does not have a smoke alarm.

      Correction: Provide a smoke alarm within each sleeping room.

      Code ATCP 72.18(11)(b)3.

    • Not serious Non-critical

      License posted in public view

      A current license is not posted on the premises in a place visible to the public.

      Correction: Post a current license in the premises in a place visible to the public.

      Code ATCP 72.07(7)

  3. Jan 13, 2026 Routine · 3 non-critical
    • Not serious Non-critical

      ROOMS IN A CLEAN CONDITION

      Carpet area near the sliding door in dining area was stained.

      Correction: ATCP 72.19 Building and Premises Maintenance. (b) Common areas. The floors, walls, and ceilings in areas other than sleeping rooms shall meet all of the following: 1. Be maintained in a clean condition. 2. Be maintained in good repair. Maintain all rooms in a clean and sanitary condition. Provide images/documents displaying the corrected deficiencies. Recommend carpet shampoo application to remove

      Code [A] ATCP 72.15 (2)

    • Not serious Non-critical

      PREMISE – EXTERIOR BUILDING

      Deck railing system did not meet the code height requirements and did not have guards installed where required.

      Correction: ATCP 72.18 Building Structure and Safety. 2) SLIPS, TRIPS AND FALLS. Except as specified under par. (c), a lodging facility shall meet all of the following: (a) Handrails. 1. At least one handrail shall be provided for a flight of stairs with more than 3 risers. The height of the handrail shall be between 30 to 38 inches measured vertically from the nose of the tread to the top of the handrail. b)

      Code [D] ATCP 72.15 (4)

    • Not serious Non-critical

      DIRECTIONS FOR ESCAPE - DESIGN

      Building evacuation diagram was not posted in sleeping rooms nor provided with guest check-in materials.

      Correction: ATCP 72.18: Building Structure and Safety. (b) Tourist rooming house. A tourist rooming house shall be provided with a building evacuation diagram and meet all of the following: 1. Be conspicuously posted in each sleeping room or provided in the check-in materials given to the guest. Pf 2. Indicate a minimum of 2 evacuation routes that lead to the exterior pursuant to sub.(4) The owner will need t

      Code [W] ATCP 72.14 (1)

  4. Oct 7, 2024 Pre-inspection · No items found

    No violations cited.