Harvest Lane
11563 HARVEST LN, Arbor Vitae, WI 54568 · Vilas County
Establishment
- Type
- Lodging (Tourist Rooming House - 1 TRH)
- Inspected by
- Vilas County Public Health
- License / ID
- GSKK-DGGGBG
- Status
- Permitted
- Phone
- (414) 379-6606
- Official record
- Vilas County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 13 | 5 |
| 2025 | 1 | 1 | 0 |
Inspections
-
Jun 29, 2026 Routine · 12 non-critical
-
Serious
Critical
POWTS access covers
The POWTS access cover was observed unlocked/missing screws.
Correction: Locked or secure the POWTS access cover to prevent general access by the public.
Code ATCP 72.17(3)(b)
-
Serious
Critical
Smoke alarms provided
Smoke alarms are not provided within each individually keyed unit.
Correction: Provide smoke alarms within each individually keyed unit at the locations specified in rule.
Code ATCP 72.18(11)(a)
-
Serious
Critical
Carbon monoxide alarms provided
A carbon monoxide alarm is not provided anywhere in the lodging facility that also contains a fuel-burning appliance.
Correction: Provide carbon monoxide alarms at the locations specified in rule.
Code ATCP 72.18(12)(a)
-
Serious
Critical
Carbon monoxide alarm installation - FBA within IKU or sleeping room
A carbon monoxide alarm is not provided outside of each separate sleeping area.
Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.
Code ATCP 72.18(12)(b)
-
Serious
Critical
Carbon monoxide alarm maintained - working order; expiration
The carbon monoxide alarm in living room is not maintained in working order.
Correction: Repair or replace the carbon monoxide alarm within 5 calendar days.
Code ATCP 72.18(12)(h)
-
Not serious
Priority Foundation
Smoke alarm installed in each sleeping room
A smoke alarm is not within each sleeping room. The bedrooms and the basement do not have a smoke alarm.
Correction: Provide a smoke alarm within each sleeping room.
Code ATCP 72.18(11)(b)3.
-
Not serious
Priority Foundation
Guards provided on stairs > 3 risers
Guards are not provided on all open sides of front door stairs and basement stairs.
Correction: Guards shall be provided on all open sides of stairs consisting of more than 3 risers.
Code ATCP 72.18(2)(b)1.
-
Not serious
Priority Foundation
Guards provided > 30" fall
The front door entrace deck is not provided with guards on all open sides that are elevated more than 30 inches above the floor or grade.
Correction: Provide guards on all open sides of the front door entrance deck that are elevated more than 30 inches above the floor or grade.
Code ATCP 72.18(2)(b)2.
-
Not serious
Priority Foundation
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Not serious
Priority Foundation
Guest-provided sanitization - sanitizer provided
A chemical sanitizer for utensils is not provided.
Correction: The chemical sanitizer must be available or made available upon request.
Code ATCP 72.20(6)(e)4.
-
Not serious
Non-critical
Exterior of building maintained
The roof soffit is not maintained in good repair, large gaps that can allow for pest entrance.
Correction: Maintain the exterior of the building in good repair.
Code ATCP 72.19(1)(c)1.
-
Not serious
Non-critical
Pest control - effective measures in place
Roof soffit openings do not prevent the entrance of pests, vermin, or wildlife.
Correction: Repair roof soffit to prevent the entrance, harborage, or infestation of pests, vermin, or wildlife.
Code ATCP 72.19(2)(a)1.
-
Serious
Critical
-
Jun 17, 2026 Follow Up · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
GENERAL MAINTENANCE
Steps leading to the basement is missing handrail on one side and guards on both sides. Font steps leading into the house has guards that are spaced >6in. The Platform leading into the house is above 24in from the ground and has guards that are spaced >6in.
Correction: Maintained establishment in a manner conducive to the health, comfort and safety of its guests. Install guards on the open sides of the staircase and reduce the guard spacing on the front steps and platform to prevent fall injury and meet code standard within 90 days (Aug. 6th, 2025). Reinspection is required. Send proof of corrections to Graydon at 715-525-1370 or email skokg@uwosh.edu.
Code [C] ATCP 72.15 (1)
-
Not serious
Non-critical
Repeat
-
May 8, 2025 Pre-inspection · 1 non-critical
-
Not serious
Non-critical
GENERAL MAINTENANCE
Steps leading to the basement is missing handrail on one side and guards on both sides. Font steps leading into the house has guards that are spaced >6in. The Platform leading into the house is above 24in from the ground and has guards that are spaced >6in.
Correction: Maintained establishment in a manner conducive to the health, comfort and safety of its guests. Install guards on the open sides of the staircase and reduce the guard spacing on the front steps and platform to prevent fall injury and meet code standard within 90 days (Aug. 6th, 2025). Reinspection is required. Send proof of corrections to Graydon at 715-525-1370 or email skokg@uwosh.edu.
Code [C] ATCP 72.15 (1)
-
Not serious
Non-critical
Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.