Elbert's Resort - Eagle's Nest (unit 6)

1070 ELBERT RD, Saint Germain, WI 54558 · Vilas County

14cited violations
4serious tier
6inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Vilas County Public Health
License / ID
SZEN-CUQQQ2
Status
Permitted
Phone
(815) 509-4326
Official record
Vilas County Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20263104
2025120
2024110
2023110

Inspections

  1. Oct 16, 2026 Follow Up · 1 non-critical, 1 repeat
    • Not serious Priority Foundation Repeat

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

  2. Oct 2, 2026 Follow Up · 4 non-critical, 4 repeat
    • Serious Critical Repeat

      Carbon monoxide alarm installation - FBA within IKU or sleeping room

      A carbon monoxide alarm is not provided outside of each separate sleeping area, the main level & the basement do not have carbon monoxide alarms.

      Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.

      Code ATCP 72.18(12)(b)

    • Serious Critical Repeat

      Windows used for exiting - 20 inches x 24 inches

      The window used for exiting has a window opening of 13 inches/width.

      Correction: Provide a window opening at least 20 inches by 24 inches irrespective of the height or width, or provide a different exit, or discontinue sleeping from that floor.

      Code ATCP 72.18(4)(g)2.

    • Not serious Priority Foundation Repeat

      Basement or ground floor sleeping room - exit types

      The provided exits from the basement or ground floor used for sleeping did not meet the following: Window egress size of 20"x24" is not met in the sleeping room on the left.

      Correction: Correct the window size and provide at least 2 separate exits from the basement left sleeping room used for sleeping or discontinue sleeping from that room.

      Code ATCP 72.18(4)(ar)1.2.

    • Not serious Priority Foundation Repeat

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

  3. Aug 25, 2026 Routine · 5 non-critical
    • Serious Critical

      Carbon monoxide alarm installation - FBA within IKU or sleeping room

      A carbon monoxide alarm is not provided outside of each separate sleeping area, the main level & the basement do not have carbon monoxide alarms.

      Correction: Provide a carbon monoxide alarm outside of each separate sleeping area within 21 feet of any door to a sleeping room and in each sleeping room, if a fuel-burning appliance is located within the sleeping room or its attached bathroom.

      Code ATCP 72.18(12)(b)

    • Serious Critical

      Windows used for exiting - 20 inches x 24 inches

      The window used for exiting has a window opening of 13 inches/width.

      Correction: Provide a window opening at least 20 inches by 24 inches irrespective of the height or width, or provide a different exit, or discontinue sleeping from that floor.

      Code ATCP 72.18(4)(g)2.

    • Not serious Priority Foundation

      Private well testing - coliform MCL

      Bacteriological testing detected coliforms in the facility's water supply.

      Correction: Correct the cause of contamination; retest to verify compliance.

      Code ATCP 72.16(2)(e)3.

    • Not serious Priority Foundation

      Basement or ground floor sleeping room - exit types

      The provided exits from the basement or ground floor used for sleeping did not meet the following: Window egress size of 20"x24" is not met in the sleeping room on the left.

      Correction: Correct the window size and provide at least 2 separate exits from the basement left sleeping room used for sleeping or discontinue sleeping from that room.

      Code ATCP 72.18(4)(ar)1.2.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

  4. Aug 2, 2025 Routine · 2 non-critical
    • Not serious Non-critical

      SMOKE DETECTORS - REQUIREMENT

      Smoke detectors are absent or not in working order.

      Correction: Provide operational smoke detectors in all sleeping rooms and required locations.

      Code ATCP 72.14 (2) (c)

    • Not serious Non-critical

      CARBON MONOXIDE DETECTORS - EXPIRATION

      The carbon monoxide detector was not replaced per manufacturer's directions

      Correction: Replace the expired carbon monoxide detector.

      Code [A] ATCP 72.145 (4)(a)

  5. May 22, 2024 Routine · 1 non-critical
    • Not serious Non-critical

      GENERAL MAINTENANCE

      Downstairs bathroom ceiling is not maintained or in good repair.

      Correction: Repair exposed venting hole in downstairs bathroom ceiling. Correct by next routine inspection.

      Code [C] ATCP 72.15 (1)

  6. Aug 31, 2023 Pre-inspection · 1 non-critical
    • Not serious Non-critical

      GENERAL MAINTENANCE

      Spacing on handrails and guardrails on deck do not meet code standards..

      Correction: Maintained establishment in a manner conducive to the health, comfort and safety of its guests. Please update guardrails around deck and handrails on the stairs of the deck to meet SPS 321.04 code standard. Please submit proof of updated deck with tape measure for reference to Sarah at 715-891-0042 or zeltens@uwosh.edu. Once proof is submitted, then permit will be issued.

      Code [C] ATCP 72.15 (1)

Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.