RecordWell Data

Starlit Sanctuary

3954 STAR LAKE RD, Star Lake, WI 54561 · Vilas County

11cited violations
3serious tier
3inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Vilas County Public Health
License / ID
ASPR-D7FH9U
Status
Permitted
Phone
(608) 201-6405
Official record
Vilas County Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026171
2025142
2024100

Inspections

  1. Nov 10, 2026 Routine · 7 non-critical
    • Serious Critical

      Carbon monoxide alarms provided

      A carbon monoxide alarm is not provided anywhere in the lodging facility that also contains a fuel-burning appliance.

      Correction: Provide carbon monoxide alarms at the locations specified in rule.

      Code ATCP 72.18(12)(a)

    • Not serious Priority Foundation

      Smoke alarm installed outside each separate sleeping area

      A smoke alarm is not provided outside of each separate sleeping area, within 21 feet of any door to a sleeping room. The upstairs living room does not have a smoke alarm.

      Correction: Provide a smoke alarm outside of each separate sleeping area, within 21 feet of any door to a sleeping room.

      Code ATCP 72.18(11)(b)2.

    • Not serious Priority Foundation

      Smoke alarm installed in each sleeping room

      A smoke alarm is not within each sleeping room. One of the downstairs bedrooms does not have a smoke alarm.

      Correction: Provide a smoke alarm within each sleeping room.

      Code ATCP 72.18(11)(b)3.

    • Not serious Priority Foundation

      Bunk beds - 2.5' spacing between beds

      A vertical separation of less than 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed was observed.

      Correction: Provide a vertical separation of at least 2.5 feet measured from the top of the lower mattress to the bottom of the frame of the upper bunk bed.

      Code ATCP 72.18(3)(d)2.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

    • Not serious Priority Foundation

      TCS foods, opened non-TCS foods, ice - removal at guest turnover

      TCS foods and opened non-TCS food items including ice are not discarded between guest stays.

      Correction: Discard all TCS foods and opened non-TCS food items including ice at guest turnover.

      Code ATCP 72.21(3)

    • Not serious Non-critical

      License posted in public view

      A current license is not posted on the premises in a place visible to the public.

      Correction: Post a current license in the premises in a place visible to the public.

      Code ATCP 72.07(7)

  2. Aug 5, 2025 Routine · 2 critical, 2 non-critical
    • Not serious Non-critical

      PERMIT NOT DISPLAYED IN PUBLIC VIEW

      Permit is not displayed conspicuously to the public.

      Correction: Post the permit in a conspicuous location to the public.

      Code ATCP 72.04 (7)

    • Not serious Non-critical

      UTENSIL SANITIZATION - CLEANING PROCEDURES

      Multi-use food contact surfaces, such as kitchen items are not being washed, rinsed and sanitized for different guests. Utensils/dishes sanitization procedure note not found in the facility.

      Correction: All multi-use utensils must be washed, rinsed and sanitized using approved methods, equipment and chemicals. Provide approved 3 compartment sink or approved commercial dish machine for this purpose or provide bleach. No utensils for food contact may be washed in a guestroom lavatory. The inspector left a copy of sanitization procedure sheet during inspection. Keep this sheet on display for guests

      Code [A] ATCP 72.11 (3)(a)

    • Serious Critical

      TOP BUNK-MISSING RAILS

      Railings are missing from a top bunk bed or guardrail is not five inches above mattress.

      Correction: Install railings that are in compliance with 16 CFR 1513. See attached photo for reference.

      Code Wisconsin Statute 97.02

    • Serious Critical

      PRIVATE WELL-WATER UNSAFE; POTABLE WATER PROVISIONS

      The well water from the well servicing this property has been determined by laboratory analysis to be unsafe per DNR 809 standards.

      Correction: Provide safe potable water from a tested and approved source on a temporary basis until the well is tested safe or a new well is drilled and the water is determined safe. Immediately discontinue use of the well's water supply for drinking, cooking and ice making purposes. Bathing is OK. Provide bottled water and ice supply from an approved source until a safe on-premise water supply is available.

      Code [E] ATCP 72.10 (3)

  3. Jul 22, 2024 Pre-inspection · No items found

    No violations cited.

Source: Vilas County Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.