RecordWell Data

Camp Minikani

875 AMY BELLE RD, Hubertus, WI 53033 · Washington County

9cited violations
2serious tier
4inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Washington Ozaukee Public Health
License / ID
HSAT-7QWJJW
Status
Permitted
Phone
(262) 251-9080
Official record
Washington Ozaukee Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026152
2025110
2024120
2023110

Inspections

  1. Jun 23, 2026 Routine · 2 critical, 3 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met. The flowmeter only shows a flow rate of 125 GPM. To meet the grandfathered turnover rate of 8 hours the facility needs to be pumping 150 GPM.

      Correction: Adjust or repair equipment to operate at a proper turnover rate. During the previous inspection, the rate was found at 140 GPM and the facility was able to adjust it to 150 GPM.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      Both guages for the sand filters are not functional.

      Correction: Adjust or repair the guages.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 210 PPM.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Serious Critical Corrected on site

      TELEPHONE ACCESSIBLE

      A telephone or other approved communication technology capable of connecting to emergency services was not working during the inspection.

      Correction: It appears the charging cord to power the cellular phone that acts as the alternative communication technology was not working. Staff fixed the issue during the inspection and got the phone to function.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

    • Serious Critical Corrected on site

      DRINKING FOUNTAIN PROVIDED

      There is no functional drinking fountain provided. The drinking fountain was not working during inspection.

      Correction: After the pool inspection was completed but before the camp inspection was completed the facility repaired the drinking fountain and provided proof via a video.

      Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED

  2. Jun 24, 2025 Routine · 1 non-critical
    • Not serious Non-critical Corrected on site

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation rate has not been met. While the exact age of this pool is not known, it was unlikely built before 1965 in which a turnover rate of 8 hours was required. During the inspection, the turnover rate was found at 8.5 hours.

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate. During the inspection staff opened some valves wider to allow more flow which brought the turnover rate to right at 8 hours.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

  3. Jun 25, 2024 Routine · 2 non-critical
    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Record your monthly pool interlock testing on your pool log.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

  4. Jun 28, 2023 Routine · 1 non-critical
    • Not serious Non-critical

      ALKALINITY OUT OF BALANCE

      The total alkalinity is above 180 ppm.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

Source: Washington Ozaukee Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.