Americinn By Wyndham Hartford Wi
1527 E SUMNER ST, Hartford, WI 53027 · Washington County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Washington Ozaukee Public Health
- License / ID
- TWET-DP2KCP
- Status
- Permitted
- Phone
- (262) 673-2200
- Official record
- Washington Ozaukee Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 6 | 0 |
| 2025 | 1 | 15 | 6 |
Inspections
-
May 15, 2026 Follow Up · No items found
No violations cited.
-
Jan 15, 2026 Pre-inspection Follow Up · 6 non-critical, 4 repeat
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 505 mV.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
REAGENTS STORAGE CONTAINER
Facility did not have the proper reagent to test for Bromine disinfectant, only for chlorine disinfectant.
Correction: Acquire R-0872 for bromine disinfectant testing, specific to the Taylor Test kits.
Code ATCP 76.17 (2)(a) - REAGENT STORAGE BOTTLES
-
Not serious
Non-critical
Repeat
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
Repeat
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises. VGBA records were unavailable for review.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Not serious
Non-critical
-
Dec 11, 2025 Pre-inspection · 6 critical, 9 non-critical
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 220 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises. VGBA records were unavailable for review.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
Both the entry railing into the pool and the pool ladder in the deep end of the pool are not fully secured to the basin and pool deck respectively.
Correction: Ensure both the railing and the pool ladder are entirely immobile. There should not be the ability to take the pool ladder or railing out of it's footings.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
DRINKING FOUNTAIN MAINTAINED
The drinking fountain was not operational at the time of the inspection.
Correction: Maintain the drinking fountain in proper clean and operational condition.
Code ATCP 76.33(1)(g)2.-DRINKING FOUNTAIN CLEAN
-
Not serious
Non-critical
POOL CLOSED SIGN
The pool area is closed but there is no 'closed' sign.
Correction: Provide a sign that indicates the pool area is closed.
Code ATCP 76.34(5) - 'CLOSED' SIGN
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
RECIRCULATION SYSTEM CONTINUOUS OPERATION
The pool recirculation system is not operational or not continuously operated. Monitoring system of the pool was not operational at the time of the inspection.
Correction: The pool must be closed immediately until the recirculation system is in place and in continuous operation.
Code ATCP 76.11(1) - RECIRCULATION SYSTEM PRESENT, CONTINUOUSLY O
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 0ppm for Bromine.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
PH
The pH is greater than 8.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
WATER CLARITY
Pool water was observed to be cloudy during the inspection.
Correction: Close the pool until the pool water is transparent and free from cloudiness and so that main drain grating and outline are readily visible from pool deck.
Code ATCP 76.16 (2) - CLARITY
-
Serious
Critical
Corrected on site
RESPONSIBLE SUPERVISOR POOL CLOSED
Responsible supervisor is not ensuring that pool is closed pursuant to ATCP 76.30, closing criteria. Management at the time of the inspection were unaware that the closing crieria for the swimming pool was met (No disinfectant in the pool, monitoring system not operational, pH too high, etc).
Correction: Have the responsible supervisor ensure that the pool is closed pursuant to ATCP 76.30, closing criteria. Management closed the pool to the public after this information was provided during the inspection.
Code ATCP 76.21 (1)(c)10. - CLOSE POOL
-
Serious
Critical
CLOSING CRITERIA-GATE OR DOOR NOT EQUIPPED TO SELF-CLOSE, LATCH, LOCKABLE
The Responsible Supervisor or operator has not closed the pool in the event that a gate or door is not equipped with a self-closing and latching mechanism, except when staffed by a lifeguard or attendant.
Correction: Close the pool in the event of a pool gate or door that is not equipped with a self-closing and latching mechanism, except when staffed by a lifeguard or attendant.
Code ATCP 76.30 (1)(i) - GATE OR DOOR NOT EQUIPPED TO SELF-CLOSE
-
Not serious
Non-critical
Source: Washington Ozaukee Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.