Greenbrier Condominiums

10635 N IVY CT, Mequon, WI 53092 · Ozaukee County

14cited violations
4serious tier
5inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Washington Ozaukee Public Health
License / ID
HSAT-7QWSGL
Status
Permitted
Phone
(414) 540-0004
Official record
Washington Ozaukee Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026252
2025171
2024111
2023110

Inspections

  1. Jul 8, 2026 Routine · 1 critical, 2 non-critical, 1 repeat
    • Not serious Non-critical

      CYANURATES 30 PPM LIMIT

      The cyanuric acid concentration is 40 ppm

      Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.

      Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC

    • Not serious Non-critical

      TEST KIT APPROVED

      Test kit is not approved

      Correction: Provide a test kit that is appoved.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Serious Critical Repeat Corrected on site

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions. Operator ordered a carbon monoxide dector for the pump room..

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  2. Jul 8, 2026 Follow Up · 1 critical, 1 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flow meter is not being maintained in operating condition. Sand was stuck on top of the flow meter.

      Correction: Adjust or repair the flowmeter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Serious Critical Repeat

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  3. Jul 22, 2025 Routine · 1 critical, 6 non-critical, 1 repeat
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flow meter is not being maintained in operating condition. Sand was stuck on top of the flow meter.

      Correction: Adjust or repair the flowmeter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER

      Operator has not logs on site cant verify testing frequency due to no logs. water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE

    • Not serious Non-critical

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical

      ALKALINITY TEST

      Pool water not tested at least once a week for total alkalinity.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY

    • Not serious Non-critical

      CYANURIC TEST

      Cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week.

      Correction: Test water for the cyanuric acid at least once a week.

      Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing. The peson in charge of taking the chemical readings has the reports at his house. Please leave the reports in the pool room for inspection.

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Serious Critical Repeat

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  4. Jul 9, 2024 Routine · 1 critical
    • Serious Critical

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  5. Jul 7, 2023 Routine · 1 non-critical
    • Not serious Non-critical

      WATER LEVEL TOO LOW

      The pool water level is not adequate for continuous effective surface skimming.

      Correction: Raise the water level until the skimming of the water surface is adequate.

      Code [B] ATCP 76.11(2)(a)

Source: Washington Ozaukee Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.