Comfort Inn & Suites (whirlpool)
1415 N PORT WASHINGTON RD, Grafton, WI 53024 · Ozaukee County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Washington Ozaukee Public Health
- License / ID
- RGON-987KH4
- Status
- Permitted
- Phone
- (262) 387-1180
- Official record
- Washington Ozaukee Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 3 | 11 | 3 |
| 2025 | 1 | 3 | 1 |
| 2024 | 1 | 0 | 0 |
Inspections
-
Jun 3, 2026 Re-inspection · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
ELECTRONIC MONITORING FREQUENCY OF TESTING
No monitoring records could be shown at the time of the inspection. The pool, with an electronic monitoring device, has not been manually tested at least once a day with an approved test kit for pH and disinfectant or sanitizer residual.
Correction: Manually test the pool at least once a day for pH and disinfectant or sanitizer residual with an approved test kit. Facility will need to send monitoring records to abigail.freeland@washozwi.gov at the beginning of each month until further notice.
Code ATCP 76.18(3)(a) - ELECTRONIC MONITORING TEST FREQ
-
Not serious
Non-critical
Repeat
-
Mar 20, 2026 Follow Up · 3 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not in working order
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
Repeat
ELECTRONIC MONITORING FREQUENCY OF TESTING
The pool, with an electronic monitoring device, has not been manually tested at least once a day with an approved test kit for pH and disinfectant or sanitizer residual.
Correction: Manually test the pool at least once a day for pH and disinfectant or sanitizer residual with an approved test kit.
Code ATCP 76.18(3)(a) - ELECTRONIC MONITORING TEST FREQ
-
Not serious
Non-critical
Repeat
-
Mar 19, 2026 Routine · 3 critical, 4 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not in working order
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 330 mV and water has not been tested manually.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
ELECTRONIC MONITORING FREQUENCY OF TESTING
The pool, with an electronic monitoring device, has not been manually tested at least once a day with an approved test kit for pH and disinfectant or sanitizer residual.
Correction: Manually test the pool at least once a day for pH and disinfectant or sanitizer residual with an approved test kit.
Code ATCP 76.18(3)(a) - ELECTRONIC MONITORING TEST FREQ
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
No chlorine observed in whirlpool. Minimum disinfectant or sanitizer level is 3.0 for Chlorine.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
RESPONSIBLE SUPERVISOR AVAILABLE AND RESPOND
Inspection lasted at least 2 hours and no responsible supervisor for the pool/whirlpool area was available during inspection.
Correction: Have the responsible supervisor respond within 15 minutes when action is needed.
Code ATCP 76.21 (1)(b) - NOT AVAILABLE WITHIN 15 MINUTES
-
Serious
Critical
Repeat
TELEPHONE ACCESSIBLE
A telephone or other approved communication technology capable of connecting to emergency services is not working or not present.
Correction: Provide a working telephone or other technology capable of connecting with emergency services.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Not serious
Non-critical
Repeat
-
May 23, 2025 Routine · 1 critical, 2 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not working.
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Serious
Critical
TELEPHONE ACCESSIBLE
A telephone or other approved communication technology capable of connecting to emergency services is not working. During the inspection, the phone was replaced and observed to be working.
Correction: Provide a working telephone or other technology capable of connecting with emergency services.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Not serious
Non-critical
-
Apr 10, 2024 Routine · No items found
No violations cited.
Source: Washington Ozaukee Public Health. History last read Nov 20, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.